Lopi Burner Burner User Manual


 
44 Installation Addenda
Travis Industries 100-01159 4040621
ADDENDUM #1 Class A Chimney Conversion Kit
Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent
this direct vent stove. The illustration below gives an overview of this type of installation. See the instructions
included with the kit for details.
! Do not exceed the maximum vertical rise (see the section "Approved Vent Configurations" starting on page 11)
allowable. Remember to set the restrictor position to the correct position (based upon the vertical rise height -
see the chart on page 11).
! The conversion kit does not work on interior masonry chimneys.
Chimney Conversion Kit A (# 931)
Metalbestos 6" I.D.
Security Chimneys 6" I.D.
Jackes-Evans 6" I.D.
Hart & Cooley 6" I.D.
Pro-Jet 6" I.D.
Chimney Conversion Kit B (# 932)
Simpson Dura-Vent 6" I.D.
Air-Jet 6" I.D.
Metal-Fab 6" and 7" I.D.
Amer. Metals 6" & 7" I.D.
Metalbestos 7" and 8" I.D.
Jackes-Evans 7" and 8" I.D.
Hart & Cooley 7" and 8" I.D.
Pro-Jet 7" and 8" I.D.
Security Chimneys 8" I.D.
Chimney Conversion Kit C (# 933)
Simpson Dura-Vent 7" and 8" I.D.
American Metals 8" I.D.
Air-Jet 8" I.D.
Metal-Fab 8" I.D.
American Metals 8" I.D.
Each Kit Contains:
Retro Connector
Retro Vertical Top
Additional Required Equipment:
4" Flex (#711 or U.L. 1777)
Termination (#991)
Co-Axial Sections
Type A Chimney
Simpson Duravent Direct
Vent Pipe Sections
(use adjustable section)
Screw the Retro
Vertical Top to the
Flex Pipe
Retro Vertical Top
(screw to chimney)
Screw the Retro
Connector to the
Flex Pipe
Retro Connector
(screw to chimney)
4" (100 mm)
Aluminum Flex
Pipe
Cut the Flex Pipe to
the chimney height
plus 3" (75 mm)