12 Installation (for qualified installers only)
Travis Industries 100-01159 4040621
Approved Vent Configurations
Restrictor Position
A restrictor is built into the appliance to control the flow rate of exhaust gases. This ensures proper
flames for the wide variety of vent configurations. Depending upon the vent configuration, you may
be required to adjust the restrictor position. The charts for approved vent configurations describe
which position the vent restrictor must be in.
Lift the stove top off the stove
and place it aside.
To Adjust the Restrictor
To Access the Restrictor
NOTE:
The restrictor is
shipped in
position #1.
This restrictor is
in position # 6
Lift the cotter pin out.
a
Slide the restrictor
adjustment rod in.
b
Replace the cotter pin
through the correct
hole on the restrictor
adjustment rod.
c
Restrictor
Positions
# 2
# 4
# 6
# 3
# 5
# 1
Measuring Vent Lengths
Vent
Horizontal
Run
Vent Horizontal Run is
measured from the start of
the horizontal section to the
end of the termination.
Vent Height is calculated to
the top of the vent on
horizontal terminations and
to the top of the termination
on vertical terminations.
Vent
Height
Vertical Elbow
NOTE:
When a horizontal elbow (90° or 45°) is
used, horizontal length is the sum of the
two lengths (H1 + H2).
H1
H2
Horizontal
Elbow
Vertical Elbow