Lopi Burner Burner User Manual


 
Installation (for qualified installers only) 15
Travis Industries 100-01159 4040621
Approved Venting Configurations with a Horizontal Termination
and Two Elbows (one 90° vertical and one 90° or 45° horizontal elbow)
If using a Snorkel Termination (14 or 36) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
5 feet
10 feet
15 feet
19' (max)
0 feet
5 feet
0 feet
0 feet
5 feet
10 feet
15 feet
Restrictor
Position # 5
NOTE:
Restrictor positions are based upon lab
tests. The ideal restrictor position may vary
slightly, especially when the termination is
near a demarkation line.
Restrictor
Position # 1
10 feet
15 feet
20 feet
24 ' (max)
0 feet
5 feet
10 feet
15 feet
20 feet
24 ' (max)
19' (max)
NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
This is considered a
vertical elbows
Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
H2
NATURAL GAS: Min. 2' Section Required
PROPANE (LP): Min. 3' Section Required