38 Optional Equipment (for qualified installers only)
Travis Industries 100-01159 4040621
5 Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
Place the LP label on top of
the control cover near the gas
control valve.
d
Remove and discard the three screws using a
slotted screwdriver of Torx T-20.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Remove and discard the
regulator, diaphram, spring
and center post.
a
b
Slotted
Screwdriver
(or T-20 Torx)
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
c
Slotted
Screwdriver
(or T-20 Torx)
6 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING: When lighting or re-lighting the pilot, the glass must be removed (see
page 22).
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
7 Install the log set (see page 24).