Safety Label 33
Travis Industries 100-01159 4040621
The safety (listing) label is on the back of the stove. A copy of the safety label is shown below.
Berkshire
Vented Gas
Fireplace Heater
Report No. 028-S-28-5
Certified for USA & Canada
Tested to: ANSI Z21.88b-1999/CSA 2.33-M99 “Vented Gas Fireplace Heater”, CAN/CGA 2.17-M91 “Gas-Fired Appliances for use at High Altitudes”,
and UL307b-1995 “Gas Burning Heating Appliances for Manufactured Homes”
Must be installed in accordance with the manufacturer’s installation instructions and all local codes, if any; if not, follow current ANSI Z223.1,
NFPA 54 and CGA B149. This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is
desired, the optional factory conversion kit must be used. This appliance uses a millivolt-type control system consisting of a gas control valve/reg-
ulator, a standing pilot burner assembly, a thermopile, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER
TO OPERATE. All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area
structure. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently
located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for
use with other gases, unless a certified kit is used. May be installed in a bedroom - in Canada install with a listed thermostat, in the USA install
per local codes.
This vented gas fireplace heater is not for use with air filters.
WARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the
owner’s and installation manual provided with this appliance. For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually
by a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present.
The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all
times. See installation instructions accompanying appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the blocked vent
shutoff system can result in carbon monoxide (CO) poisoning and possible death.
Vented gas fireplace heater - Not for use with solid fuel.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified
service person.
Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.
Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct connection).
10850 117th Pl. N.E. Kirkland, WA 98033
Minimum Clearances to Combustibles
Stove Top to Sidewall......................... 10” Alcove Min. Height.................................... 58”
Stove Top to Backwall........................ 5” Alcove Max. Depth.................................... 45”
Stove Top to Cornerwall..................... 5” Alcove Min Width...................................... 46-3/4”
Glass Front of Unit.............................. 36”
L.P.
N.G. L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)* . . . . . . 31,000 31,000 Minimum Inlet Pressure (inches W.C.) . . . . . . . . 11” 5.5”
Input Rate on “LO” (BTU/Hr)* . . . . . 23,000 24,900 Maximum Inlet Pressure (inches W.C.) . . . . . . . . 13” 7”
Manifold Pressure on “HI” (inches W.C.) . . . . . . 10” 3.5”
This appliance is equipped only for altitudes 0-2000 ft. (0-610 m) in USA; in Canada, 0-4500 ft. (0-1370 m).
Electrical Rating: 115v, 1.5 Amps, 60 Hz
Manufacture 2000 Jan. Apr. Jul. Oct.
Date: 2001 Feb. May Aug. Nov.
2002 Mar. Jun. Sep. Dec.
0371