Lopi Burner Burner User Manual


 
Installation (for qualified installers only) 21
Travis Industries 100-01159 4040621
! If the vent configuration is installed incorrectly the vent may cause the flames inside the heater to lift or
ghost a dangerous situation. Inspect the flames after installation to insure proper performance. If
the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the heater and
contact the dealer for information on remedying the problem.
! Failure to properly adjust the air shutter may lead to improper combustion and a safety hazard. Consult
your dealer or installer if you suspect an improperly
The flames should burn right off
the top of the burner ports (if they
are too blue, adjust the air control).
If the flames are lifting, yet the
vent configuration is correct,
contact your dealer.
Burner Pan
Burner Ports
(holes)
If the flames are ghosting, yet the
vent configuration is correct,
contact your dealer.
7 Turn the flame adjust knob to its highest position - the flames should be a maximum 9 to 10 tall.
Check the flame on low position. The flames should burn off of each burner hole. If the heater does
not work correctly, contact your dealer for a remedy.
8 Give this manual to the home owner and fully explain the operation of this heater.