BLOWER DATA
ML180UH045E36A PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Various Blower Speeds
High Medium-High Medium Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1380 265 1155 165 995 120 975 115 945 105
0.10 1345 270 1120 175 950 120 880 105 865 100
0.20 1320 285 1080 190 900 125 805 105 700 85
0.30 1290 295 1055 200 875 135 750 110 640 90
0.40 1265 310 1010 205 825 145 710 120 595 95
0.50 1230 315 990 215 790 155 660 125 535 100
0.60 1190 330 945 230 750 165 630 135 500 110
0.70 1165 340 915 235 705 170 570 140 435 115
0.80 1130 350 880 245 670 180 535 150 380 120
ML180UH070E36B PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Various Blower Speeds
High Medium-High Medium Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1415 265 1330 170 1215 135 1175 125 1075 85
0.10 1415 280 1295 170 1145 145 1130 130 955 95
0.20 1355 290 1225 185 1110 150 1080 140 885 100
0.30 1330 300 1190 200 1060 160 1035 155 825 110
0.40 1290 310 1155 205 1015 175 970 160 770 120
0.50 1245 325 1115 215 980 180 930 170 695 125
0.60 1225 335 1045 230 920 190 865 180 625 135
0.70 1190 350 1000 235 855 205 790 190 540 140
0.80 1160 365 925 245 790 205 735 200 445 145
ML180UH090E48B PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Various Blower Speeds
High Medium-High Medium Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00 1785 380 1570 270 1440 220 1395 190 1190 120
0.10 1755 395 1535 275 1420 230 1350 205 1140 130
0.20 1730 415 1505 290 1380 245 1310 215 1110 145
0.30 1690 435 1460 305 1345 260 1275 230 1065 155
0.40 1645 440 1435 320 1310 270 1240 240 1010 165
0.50 1615 455 1395 335 1265 285 1180 255 955 180
0.60 1590 470 1350 350 1210 290 1150 265 915 185
0.70 1545 475 1300 360 1175 305 1095 275 860 200
0.80 N/A N/A 1270 370 1140 310 1040 285 820 210