HP (Hewlett-Packard) 403349-003 Fan User Manual


 
Removal and replacement procedures 68
You can replace the HEX units during operation.
The following tools are required for installation:
T-25 Torx driver
Adjustable wrench or pipe wrench
Removing the heat exchanger unit with ball valves
NOTE: For this procedure, remove the fan unit seated directly behind the heat exchanger unit
you will remove.
1. Remove the fan unit ("Removing the fan unit" on page 51).
2. Remove the air deflector plate ("Removing the air deflector plate" on page 33).
NOTE: The heat exchanger units are deep-seated within the MCS unit. To access the
connections described in the following steps, extend your arm inside the MCS unit until you
come in contact with the appropriate connectors.
3. Disconnect the temperature sensor connector from the HEX unit.