Heatiator ECO-WINS18 Indoor Fireplace User Manual


 
Heatilator • ECO-WINS18 • 7065-132B • August 29 2011
38
Ovalizingroundstainlesssteellinerstoaccommodatethe
linerpassingthroughthedamperregionofareplaceisan
allowableandacceptablepractice.
Ensure that the ovalization is minimized to the extent
requiredtotthroughthedamper.
J. Ovalizing Round Stainless Steel Liners
FireRisk.
DoNOTpackinsulationorothercombustibles
betweenspacers.
• ALWAYSmaintainspeciedclearancesaround
ventingandspacers.
• Installspacersasspecied.
Failuretokeepinsulationorothermaterialawayfrom
ventpipemaycausere.
WARNING
K. Chimney Height / Rise and Run
Tobe surethat yourHeatilatorinsertburnsproperly,the
chimneydraft(staticpressure)shouldbeapproximately-0.10
incheswater column(W.C.) duringahighburnand-0.04
inchesW.C.duringalowburn,measured6inches(152mm)
abovethetopoftheinsertafteronehourofoperationateach
burnsetting.
NOTE:Theseareguidelinesonly,andmayvarysomewhat
forindividualinstallations.
• Thisproductwasdesigned forand testedon a6 inch
(152mm)chimney,14to16 feet(4.27-4.87m)high,(in-
cludesapplianceheight)measuredfromthebaseofthe
appliance.
• Thefurtheryourstackheightordiametervariesfromthis
conguration,thepossibilityofperformanceproblemsex-
ists.
• Chimneyheightmayneedtobeincreasedby2
-3%per
each1000feet(304.8m)abovesealevel.
• Itisnotrecommendedtouseoffsetsorelbowsataltitudes
above4000feet(1219.2m)abovesealevelorwhenthere
areotherfactorsthataffectuedraft.
FireRisk.
Thisappliancereliesuponnaturaldrafttooperate
properly.
• Chimneyheightsexceeding25feet(7.62m)from
baseofappliancemaycreateanover-draftsituation.
• Overdraftconditionmaycreateover-ring.
Over-ringmayignitecreosoteand/ordamageappli-
anceandchimney.
WARNING
FireRisk.
Failuretoinstallafullrelinemaycause:
• Creosoteaccumulationcreatingincreasedriskof
chimneyre.
• Loseprotectiontocombustiblesurfacesfromthe
linerincaseofre.
• Poorperformanceandstart-ups.
• Lessaccesstochimneyforrequiredmaintenance.
WARNING