19Heatilator • ECO-WINS18 • 7065-132B • August 29 2011
Note: These are generic drawings and may not represent your specic model.
Baffle
Blanket
Latch Cam
Spacing Washers
Bafe&Blanket
OptionalBlower
ChimneySystem
Firebrick&AshRemoval
Door&GlassAssemblies
DoorHandle
Frequency
MONTHLY
or
AfterEvery
CordofWood
Bafeandblanketplacementiscriticalto
heatoutput,efciencyandoveralllifeofthe
unit.Makesurethebafeispushedallofthe
waytothebackofthereboxandtheblanket
islayingat.Inspectbafeforcracks.
YEARLY
or
AfterEvery
4Cordsof
Wood
Vacuumtheblowerimpellers.
EVERY2
MONTHS
or
AfterEvery
4Cordsof
Wood
T
hechimneyandchimneycapmustbein-
spectedforsootandcreosoteeverytwo
monthsduringtheburnseasonormorefre-
quencyifchimneyexceedsorisunder14-16ft
(4.3m-4.8m)measuredfrombottomofappli-
ance.
Thiswillpreventpipeblockage,poordraft,
andchimneyres.
Alwaysburndrywoodtohelppreventcap
blockageandcreosotebuild-up.
WEEKLY
or
AfterEvery
25Loadsof
Wood
Ashesmustbecoolbeforeyoucandispose
oftheashesinanon-combustiblecontainer.
Firebrickisdesignedtoprotectyourrebox.
Afterashesareremoved,inspectthere-
brickandreplacerebricksthatarecrum-
bling,crackedorbroken.
WEEKLY
or
AfterEvery
25Loadsof
Wood
Keepdoorandglassgasketingoodshapeto
maintaingoodburntimesonalowburnsetting.
Totest:placeadollarbillbetweenthestove
anddoorandthenshutthedoor.Ifyoucan
pullthedollarout,removeonewasherfrom
doorhandlebehindlatchcamandtryagain.If
youcanstillpullitout,replacethedoorgasket.
Checktheglassframeforloosescrewsto
preventairleakage.Checkglassforcracks.
WEEKLY
or
AfterEvery25
LoadsofWood
Checkthedoorlatchforproperadjustment.
Thisisveryimportantespeciallyafterthedoor
ropehasformedtothestoveface.
Checkdoorhandleforsmoothcamoperation.
Task
CAUTION! Allow the appliance to completely cool
down before performing any cleaning or maintenance.
Starttherstinspectionaftertherst2monthsofuse,
or ifperformancechanges, andadjustyour schedule
accordingly.Maintenanceisrequiredforsafeoperation
andmustbeperformedtomaintainyourwarranty.
F. Quick Reference Maintenance Guide