N. Blower Operating Instructions
1. The blower will turn on/off automatically when set to
AUTO.Figure 14.1.
2. WhensettoMANUAL,thefanwillturnon/offonlywhen
youturnitonoroff.Thissettingover-ridestheinternal
snapdisc.
3. BlowerControlsarelocatedonbottomleftofappliance.
M. Blower Control Box & Snap Disc
Operating Instructions
Figure 14.1
1.Initial (cold) startup: RaisetheBurnRateAirControl
allthewayuptotheHighsetting.
Theblowertendsto
cooltheappliance.Leavethebloweroffuntiltheburnis
wellestablished,i.e.,30minutes.
2. High Burn Setting: RaisetheBurnRateAirControlall
thewayuptotheHighsetting.Theblowermayremain
on.
3. Medium or Medium High Burn Setting:BurnRateAir
Controlisclosedthenopenedto1inch(pullup).The
blowermayremainon.
4. MediumLow Burn Setting:BurnRateAirControlis
closed then opened to 1/4 inch to 1/2 inch (pull up).
Leavetheblowerofffortherst30minutesuntiltheburn
iswellestablished.
5. Low Burn Setting:  Burn RateAir Control is closed
(downposition).
Leavetheblowerofffortherst30min-
utesuntiltheburniswellestablished.
NOTE: Formaximumefciencyandlowestemissions,
when operating the blower in either the automatic or
manualsettingforthelowandmediumlowburnsettings
leavethebloweroffuntiltheburniswellestablished,i.e.,
30minutes,
When reloadingthe appliance,raise theBurn RateAir
ControlallthewalltotheHighsettingfor5to15minutes
beforesettingtothedesiredburnrate.
6. Theblowerisequippedwitharheostat(speedcontrol).
The highest blower speed is obtained by turning the
rheostaton,thenadjustingbacktowards“OFF”asfaras
possiblewithoutturningthebloweroff.Foralowblower
speed,turnthecontrolknobclockwiseasfaraspossible