Heatiator ECO-WINS18 Indoor Fireplace User Manual


 
25Heatilator • ECO-WINS18 • 7065-132B • August 29 2011
6
Getting Started
Installer’s Guide
A
. Design and Installation Considerations
2.Priortoinstalling,determinethefollowing:
• Typeofchimneyconnectortobeused
·singlewall,6inch(152mm)diameter,stainlesssteel,
or
·doublewall,6inch(152mm)diameter,stainlesssteel
• Consultpages 32 and 33forclearancestocombustibles
• Poweroutletlocatedclosebyforoptionalblower
Draftisthepressuredifferenceneededtoventappliances
successfully.Whenaapplianceisdraftingsuccessfully,all
combustion byproducts are exiting the home through the
chimney.
Considerationsforsuccessfuldraftinclude:
• Preventingnegativepressure
• Locationofapplianceandchimney
T
obesurethatyourapplianceburnsproperly:
• Duringalowburn,thechimneydraft(staticpressure)should
beapproximately-.04inchwatercolumn(W.C.)
• Duringahighburnthechimneydraftshouldbeapproximately
-.10inch(W.C.)
• MeasuretheW.Cat6inches(152mm)abovethetopofthe
applianceafteronehourofoperationateachburnsetting.
NOTICE:Hearth&HomeTechnologies assumesno
responsibilityfortheimproperperformanceoftheappliance
systemcausedby:
B. Draft
Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.
• Consultinsurancecarrier,localbuilding,reofcialsor
authoritieshavingjurisdictionaboutrestrictions,installation
inspection,andpermits.
CAUTION
WARNING
• DONOTCONNECTTHISUNITTOACHIMNEY
FLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
Asphyxiation Risk.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.
• Operatingappliancewithoutfullyassemblingall
components.
• Operatingappliancewithoutlegsattached(ifsuppliedwith
unit).
• DoNOTOverre-Ifapplianceorchimneyconnectorglows,
youareoverring.
Any such action that may cause a re hazard.
WARNING
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbe
voidedby,thefollowingactions:
• Inadequatedraftduetoenvironmentalconditions
• Downdrafts
• Tightsealingconstructionofthestructure
• Mechanicalexhaustingdevices
• Overdraftingcausedbyexcessivechimneyheights
• Idealperformanceiswithheightofchimneybetween
14-16feet(4.26-4.88m)measuredfromthebaseof
theappliance.
Heatilatorwoodinsertsaredesignedforfactory-builtnon-
combustible replaces that have been installed in accor-
dancewiththeNational,Provincial,Stateandlocalbuilding
codes.
1.Priortoinstallingthewoodinsert:
• Havethechimneyandadjacentstructureinspectedand
cleanedbyqualiedprofessionals.Heart&HomeTech-
nologiesrecommendsthatNFIorCSIAcertiedprofes-
sionals, or technicians under the direction of certied
professionals,conductaminmumofaNFPA211Level2
inspectionofthechimney.
• Replacecomponentpartsofthechimneyandreplace
asspeciedbytheprofessionals.
• Ensurealljointsareproperlyengagedandthechimneyis
properlysecured.