H. Burn Rate Air Control
• Theairsupplyenters attheupperfront ofthe rebox,
nearthetopoftheglassdoor.
• Thispreheatedairsuppliesthenecessaryfreshoxygen
tomixwiththeunburnedgases,helpingtocreatesec-
ond,thirdandfourthcombustions
• ThisairisregulatedbytheBurnRateAirControl.
• TherearefoursettingsHigh,Medium-High,Medium-Low
andLow.
• WhenthecontrolisraisedallthewayupitisontheHigh
settingandwhenpushedallthedownitisontheLow
setting.Figure 10.1.
I. Burn Rates and Operating Efciency
For maximum operating efciency
1. Followtheinstructionsbelowforeachburnrateforthe
BurnRateAirControl.Figure 10.1.
2. Burndry,well-seasonedwood.
Burn Rates
1. Starting a Fire
• OpentheBurnRateAirControlbyraisingitalltheway
tothetopfortheHighsetting.

• Theblowertendstocooltheappliance.Leavetheblower
offuntiltheburniswellestablished,i.e.,30minutes.
• Afterloadingtheappliancewithwoodandstartingthe
re,settheBurnRateAirControlstothedesiredsetting
byfollowingtheburnrateinstructionsbelow.
2. High Burn Rate - Maximum Heat* - 30,000+ BTU/hr
•
Raise theBurn RateAir Controlall theway upuntil it
stops(topmarker)toafullyopenposition.
•
Besureandmonitortherecloselywhileinthissettingto
avoidoverringyourstove.
3.
Medium-High Burn Rate* - 15,000 to 30,000 BTU/hr
• Raise theBurn RateAir Control tothe Medium High
marker.
Blowermayremainon.
4.
Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
• RaisetheBurnRateAirControltotheMediummarker.
Leavethe bloweroff untiltheburnis wellestablished,
i.e.,30minutes.
5. Low Burn Rate* - Below 10,000 BTU/hr
• LeavetheBurnRateAirControlatthebottommarker.
Leavethe bloweroff untiltheburnis wellestablished,
i.e.,30minutes.
*NOTE:
Theseareapproximatesettings,andwillvarywith
typeofwood orchimney draft.Duetoaltitudeandother
environmentalcircumstances,thisoperationalinformationis
aguidelineonly.
Figure 10.1 - Burn Rate Air Control
-HIGH
-MEDIUM HIGH
-MEDIUM
-LOW