11Heatilator • ECO-WINS18 • 7065-132B • August 29 2011
CORRECT POSITION
INCORRECT POSITIONS
Improperbafeplacementmaycause:
• Overheatingofrebox
• Overheatingthechimney
Bafemustbeplacedproperly(seeinstructions)
Replacebafeifdamagedormissing.
WARNING
Fire Risk
J. Correct Bafe & Blanket Placement
CeramicBlanketandBafeBoardareNOT
incontactwiththebackoftherebox.
CeramicBlanketisNOTincontactwiththe
backofthereboxandNOTevenwiththe
BafeBoardinthefront.
CeramicBlanketisbunchedupattheback
ofthereboxandNOTevenwiththeBafe
Boardinthefront.
Ceramic Blanket
Back of Firebox
Baffle Board
CeramicBlanketandBafeBoardMUSTbe
in contact with the back of the rebox and
evenwitheachotherinthefront.
Ceramic Blanket
Back of Firebox
Baffle Board
Figure 12.1 - Correct Bafe and Blanket Positions Figure 12.2 - Incorrect Bafe and Blanket Positions
Note: Thisaregenericdrawingsandmay
notrepresentyourspecicmodel.
NOTE: Amissing,damagedorimproperlypositionedbafe
isdangerousandmaycausedamageandpoorefciency.
Itwillalsovoidyourwarranty.