Heat & Glo LifeStyle 550TRSI-AUF Indoor Fireplace User Manual


 
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12
20
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Duetohightemperatures,theapplianceshouldbelocat-
edoutoftrafcandawayfromfurnitureanddraperies.
NOTICE:Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
REAR FLUE,
HORIZONTAL TERMINATION
TWO 90º ELBOWS
REAR FLUE
NO ELBOWS
REAR FLUE
ONE 90º ELBOW
ALCOVE
INSTALLATION
TOP FLUE
ONE 90º ELBOW
A
B
J
C
K
E
B
B
B
I
D
D
F
G
H
3 in. (76 mm)
N
D
A
L
M
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
1 in. (25 mm) GAP TO WALL ON EACH SIDE
1/2 in.
13 mm
C
L
A B C D E F G H I J K L M N
550TRSI-AUF
550TRSILP-AUF
in. 42 37 59-1/2 48-1/2
See Section D.
Mantel Projections
16-1/2 15-1/16 7-1/2 34-1/4 29-3/4 39 40-5/8 7-7/8 68-3/4
mm 1067 940 1511 1232 419 343 191 870 756 991 1033 200 1737