Save These Instructions 3-90-775 Pellets or Corn/Pellet Mixture Only
Vacuum to clean.
Whenever cleaning burn pot air chamber.
To remove igniter;
• Loosen wing screws and remove cover on front of
burn pot.
• Using a 5/16" wrench, remove the two black
screws above the cleanout. The igniter and brack-
et are now free.
• Slide the insert body out of the mounting frame.
• Locate the pale blue and yellow wires entering at
the bottom of the feeder body.
• Remove wire ties as needed to loosen the igniter
wires.
• Pull the igniter and bracket out from the front until
the wire disconnects are accessible.
• When installing igniter, reverse these steps and be
sure that the plastic coated wires are pulled all the
way to the rear of the feeder.
• Re- tie all wires clear of all hot or moving parts.