Pellets or Corn/Pellet Mixture Only 3-90-775 Save These Instructions



A combustion blower is used to extract the combus-
tion gases from the rebox. This causes a negative pres-
sure in the rebox and a positive pressure in the venting
system. The longer the vent pipe and more elbows used
in the system, the greater the ow resistance.
      

 30 Lineal ft. Vertical*

4" Pl Vent Pipe: 30 Lineal ft. Vertical*
4" Pl Vent Pipe: 14 ft. Vertical w/1-90
o
and 12 lineal ft.
horizontal*
        

Vertical 90
o
or T: 2.5'
Vertical 45
o
: 1.5'
Horizontal 90
o
or T: 5.0'
Horizontal 45
o
: 2.5'

20 Lineal ft. vertical*
8 Lineal ft. vertical w/1-90
o
& 8 lineal ft. horizontal*
        

Vertical 90
o
or T: 2.0'
Vertical 45
o
: 1.0'
Horizontal 90
o
or T: 4.0'
Horizontal 45
o
: 2.0'
* Long runs of ex or PL vent pipe installed directly
vertical from the ue stub may require more frequent
cleaning due to y ash falling off inside and collecting
directly above the combustion blower outlet.
Any use of horizontal venting will require more
frequent cleaning. It is the responsibility of the installer
to make sure the entire ue conguration is accessible
for cleaning.
Stainless steel ex vent is only allowed for use in
masonry replaces and chimneys or in factory built wood
burning replace installations when used as a liner for
a class A metal chimney. All pellet vent pipe must be
secured together by means provided by pipe manufac-
turer. The vent pipe must be secured to the appliance
ue collar with a minimum of three screws.
It is also recommended that you seal all vent pipe
joints with high temperature silicone.

       

        







Only LISTED type L or PL Pellet venting compo-
nents may be used.
NO OTHER type of venting materials or compo-
nents may be used.
Substitute or damaged vent components may
impair safe operation.


Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage.
Read and Refer to your owner's manual.
For assistance or additional information, consult a
qualied installer, service agency or your dealer.








