Save These Instructions 3-90-775 Pellets or Corn/Pellet Mixture Only


During operation in ROOM TEMP/ AUTOMATIC
mode, the appliance will shut down naturally when
demand is met or exceeded. In other modes of opera-
tion, the unit will shut-down only if or when it runs out
of fuel.
To kill or stop a re, turn the mode selector dial to
"OFF". The shut down cycle will slow or stop the
feeder to gradually cool the re and ensure that all of
the exhaust gases are safely expelled before stopping
the combustion blower. This not only ensures removal
of all smoke and gases, it also keeps the re from at-
tempting to travel into the fuel storage hopper. For this
reason; Hearth & Home Technologies recommends
installing a battery back-up in areas where frequent
power outages are experienced. (Also see page13)



The best way to kill a re, especially at the end of the
heating season, is to simply allow it to run out of fuel.

An added feature for those times when you'd like to
unwind watching a re but yet do not want all the heat.
With the igniter switch in the "MANUAL" position and
the mode selector in "STOVE TEMP", your tempera-
ture dial can be set up to a #3 and the distribution
blower will be disabled. As you turn up the tempera-
ture dial and the re
begins to burn hotter,
the distribution blower
will begin to operate.






1. With the mode selector in the "OFF" position, and
the Feed Adjuster  on "Test", plug the power
cord into a properly grounded receptacle.
2. Fill the hopper with DRY fuel.
3. Turn the FEED ADJUSTER dial to "Test". This will
run the feed motor for one minute. If you begin to
see fuel entering the burn pot, you can stop the
test cycle. Return to #4 or #5 to start out.
4. Position the Igniter switch to AUTOMATIC.
5. Turn the mode selector dial to the desired mode.
This will start the combustion blower, feeder, and
igniter operating. 


6. After the initial feed cycle is typically when you'll
begin to see sparks, smoke, or ames.

Once the Distribution Blower begins operation, your
re is well established. Now, you can make any
desired adjustments to the temperature dial. Remem-
ber, in STOVE TEMP, the temperature dial uses the
inner portion of the scale (#1 thru 7). In ROOM TEMP,
select the desired temperature in Fahrenheit from 50
to 90 degrees.
The ames should appear brisk and bright. If you see
deep orange and lazy ames, it is usually an indica-
tion that the burn pot needs to be cleaned. Refer to
the Maintenance Section of this manual.
 Keep combustible mate-
rials, gasoline, and other ammable vapors or liquids
clear of this appliance.
Do  store ammable materials in the vicinity
of this appliance.
DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIL.
DO NOT USE CHEMICALS OR FLUIDS TO
START A FIRE.
Keep all such liquids well away from the heater while
it is in use, combustible materials may ignite!