Harman Stove Company P35I Indoor Fireplace User Manual


 
16
Pellets or Corn/Pellet Mixture Only 3-90-775 Save These Instructions



If installing using the optional zero clearance cabinet,
Item #1-00-774257, the venting will need to exit through
the top of the cabinet. The vent can be vertical or
horizontal after leaving the cabinet. Once clear of the
cabinet, a 90 degree elbow can be installed for rear
termination as shown. Do not allow vent pipe seams to
fall within the cabinet wall. Use proper wall thimble as
supplied by the venting manufacturer.
If nishing the interior with stone or masonry, the venting
can be installed without the appliance. Install the cabinet
and secure the venting using the Flue Rough-in Support
#1-00-774283.
The top of the chimney must also be sealed.
Otherwise, it can become a nesting area or a
water trap.
If passing through combustible
material, the proper thimble from the
vent manufacturer must be used.
Masonry wall
3" Clearance
Zero Clearance Cabinet
shown with Flue Rough-in
Support
Vent pipe seams must be
accessible.
Vertical Venting may be used in a constructed chase
providing all clearances to combustibles are met.
Proper wall pass-thru device
as recommended by the
venting manufacturer.










 When installed in a rear vent
conguration, the maximum BTU
may be reduced due to elevated ESP
temperatures associated with the
horizontal exhaust stream.