Harman Stove Company P35I Indoor Fireplace User Manual


 
17
Save These Instructions 3-90-775 Pellets or Corn/Pellet Mixture Only





1. An outside air inlet must be provided for combus-
tion air, and must remain clear of leaves, debris,
ice, and/or snow. The outside air path must be
unrestricted while the appliance is in operation.
2. The combustion air intake system must be of
metal construction. It must permit zero-clearance
to combustible materials, and contain a rodent
screen.
3. The appliance must be secured to the mobile
home structure by bolting it to the oor. Use the
correct length lag-bolts through the same holes
that secured the appliance to the shipping pallet.
4. The appliance must be grounded to the metal
framing of the mobile home.
5. All clearances to combustibles and oor protection
requirements must be followed.
6. Follow the vent manufacturer's instructions when
installing in a mobile home. Use silicone or equiva-
lent to create an effective vapor barrier where the
chimney or other component penetrates to the
exterior of the mobile home.
7. Installation shall be in accordance with the Manu-
factured Home and Safety Standard (HUD) CFR
3280, Part 24
8. The appliance must never be installed in a room
designated for sleeping.
9. The space heater must be connected to a fac-
tory built chimney conforming to CAN/ULC-S629.
Maximum 8 inch diameter. Chimney must be
removable to allow transport of mobile home.


Installation must comply with Manufactured
Home and Safety Standard (HUD), CFR
3280, Part 24.



 
Do  cut through:
Floor joist, wall studs, or ceiling trusses.
Any supporting material that would affect the
structural integrity.

Never draw outside combustion air from:
Wall, oor or ceiling cavity.
Enclosed space such as an attic or garage
There are a few holes in the bottom of the insert
mounting frame which can be used for lag bolts. Use
at least two of these holes for securing the appliance
to the replace oor in a mobile home installation. The
installer will need to determine and obtain the properly
sized lag bolts and masonry anchors.
Four 5/16 -18 Leveling
bolts may be installed
in each corner
Numerous holes allow
for lag bolts (2 min.)in
mobile home installation