Genie directlift 2060 Garage Door Opener User Manual


 
For Help,call 1-800-35-GENIE or visit www.geniecompany.com
9
C
H SET LIMIT SWITCHES AND
FORCE CONTROLS
Adjustment 1:
Rough Setting of Limit Switches
A Setting Close Limit Switch (Figure 9):
Check that Carriage Assembly is disengaged.
With garage door fully closed,slide Close Limit Switch
toward Carriage until white lever is fully lifted.
Tighten Set Screw. Do Not over-tighten.
B Setting Open Limit Switch:
Manually open garage door to full open position.
Slide Open Limit Switch toward Carriage until white lever
is fully lifted.
Tighten Set Screw. Do not over-tighten.
Re-engage Carriage Assembly.
Setting Force Controls and Final Adjustment of
Limit Switches
A CLOSE ADJUSTMENT
On front panel of Power Head find adjusting screw
marked “CLOSE” (Figure 9).
Gently turn screw counterclockwise until it stops.
Very little force is required to turn adjusting screw.
Press Wall Console to close garage door.
Observe if door stops at “CLOSE”limit switch.
If door is fully closed—adjustment is finished.
Go to “OPEN”Adjustment.
If door stops but is not fully closed,
a. Measure distance between bottom of door
and floor.
b. Move“CLOSE”Limit Switch that same distance
toward door.
If door stops and/or reverses before reaching the
CLOSE”Limit Switch
a.
Slightly increase CLOSE Force setting (clockwise).
If door reverses after contacting floor, move Limit
Switch toward Power Head.
If door fails to move,check Safe-T-Beam® System.See
Troubleshooting Section,page 14.
Tighten Limit Switch Set Screw.Do not over-tighten
(strip) Limit Switch Set Screw.
Open adjustment next page.
WARNING
The garage door opens rapidly, and can cause serious
injury or death.
Keep the path clear.
Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.
Set the door Opener to use the minimum force needed
to open the door.
NOTE
Little effort is required to turn the Force
Adjusting Knobs.
If the door stops moving while opening or
closing, adjust the Open Force or Close Force
Controls
slightly clockwise (to slightly
increase the force) and retry the step.
The Open Force and Close Force Controls are to
be set to the
minimum force necessary to
ensure the door smoothly opens and
closes completely.
Ensure the Carriage Assembly is engaged and is
between the two Limit Switches before
operating the Opener.
Figure 9 Making Force Adjustments
OPE
N
C
L
OS
E
OPEN
CLOS
E
FORCE
CONTROLS
MAINTENANCE AND ADJUSTMENTS