A Monthly:
Door springs and door hardware:
Oil door roller,bearings,and hinges using silicone
lubricant or light oil.
Balance Door.
Close door.
Release Carriage Assembly from Rail Assemblybypulling
the Emergency Release Knob towards the door.
Raise door manually 3'- 4' and verify that door staysat
thatposition.SeeCheck Step 2onpage 5.
ReattachCarriageAssembly to RailAssembly:
a.
Pull the Emergency Release Knob towardPower Head.
b. Close door.
Contact Reverse Test.
Perform Adjustment 2 on page 10.
B Yearly:
Wipe off old excess lubricant from Drive Screw.
Lubricate Drive Screw with Genie Lubricant (GLU-3)
C As needed
Replace lightbulbs.
NOTE
When the door is 3' - 4' above the ground, the door
should stay open. Slight movement is acceptable. If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1-800-35-GENIE.
WARNING
Do not operate door automatically or manually if springs
are broken. Contact a Genie Factory Authorized Dealer for
service or call Customer Service at
1-800-35-GENIE.
WARNING
If the door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 10. If the Opener
still fails,contact a Genie Factory Authorized Dealer for
service or call Customer Service at
1-800-35-GENIE.
NOTE
Use ONLY Genie Lubricant (GLU-3). Other lubricants
may damage the Opener.
FCC AND IC CERTIFIED
All devices comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
Screw Drive Garage
Part No.
GLU-3
Door Opener Lubricant
GLU-3
Lubricant
MAINTENANCE
WARNING
TO REDUCE THE RISK OF
SEVERE INJURY OR DEATH
1 READ AND FOLLOW ALL INSTRUCTIONS.
2 Never let children operate or play with the Door
Controls. Keep the Remote Control away from
children.
3 Always keep the moving door in sight and away
from people and objects until the door is
completely closed. NO ONE SHOULD CROSS THE
PATH OF THE MOVING DOOR.
4 NEVER GO UNDER A STOPPED, PARTIALLY
OPEN DOOR.
5 Test Opener monthly. The door MUST reverse on
contact with a 1-1/2" high object (or a 2" x 4"
board laid flat) at the center of the doorway on the
floor. After adjusting either the Force or the Limit
of travel, retest the Door Opener. Failure to adjust
the Opener properly may cause severe injury
or death.
6 When possible use the Emergency Release only
when the door is closed. Use caution when using
this Release with the door open. Weak or broken
springs are capable of increasing the rate of door
closure and increasing the risk of severe injury
or death.
7 KEEP GARAGE DOORS PROPERLY BALANCED. See
garage door Owner's Manual. An improperly
balanced door increases the risk of severe injury
or death. Have a Genie Factory Authorized Dealer
make repairs to cables, spring assemblies, and
other hardware.
8 SAVE THESE INSTRUCTIONS.
IMPORTANT
SAFETY
INSTRUCTIONS
WARNING
Use the Wall Console included with Opener. Any other
wall console can cause the Opener to operate
unexpectedly and the light to stop working.
2060-3060 eng.qxd 11/9/05 11:02 AM Page 13