Genie 3531835447 Garage Door Opener User Manual


 
Problem What To Do
Opener does not run 1. Check power source.
from Remote Control A. If Opener isconnected to an outlet:
Plug a working lamp into outlet used for Power Head.
If lamp glows, power source and outlet are OK.
. If not, check fuse or circuit breaker or non-compatible GFCl.
NOTE:A licensed electrician must replace non-compatible GFCI's.
B. If Opener is connected to a wiring box:
. Check fuse is not blown, or circuit breaker is"Closed" (not tripped).
. If still no power, have a licensed electrician check circuit and wiring.
2. If power is OK:
. Check connections at Power HeadTerminals (seeWall Console Installation page 18), tightening any
loose connections.
Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive
Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-3S-GENIE.
Door Opener starts . Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires).
for no apparent reason Replace any shorting Staples and shorted Wires.
. Was Remote Control lost or stolen? If so, eraseall Remote Control codes from Receiver's memory
and reprogram for remaining remote controls. (SeeEraseAll Receiver Memory on page 22).
,x ,,
Door starts down, then . Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 20).
stops before it is Adjust as needed.
completely closed . Check for shorted Wires.
. Check garage door for binding.
Door starts down, then If a new installation, check Door Arm position.
stops and goes back up Check operation of Contact Reversefunction.
Check Safe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
®
CheckSafe-T-Beam Systemdiagnostic code.
Check CloseForceadjustment (seeSetLimit Switchesand ForceControls on page 20). Adjust as needed.
. Checkgaragedoor for binding.
Door will only run closed CheckOpen Limit Switch for a short circuit and for proper wiring.
. CheckOpen Force adjustment (seeSetLimit Switchesand ForceControls on page 20). Adjust asneeded.
. Checkcondition of garage door and door spring(s).
. J:_R __}6.Ifyou suspect a problem with the garage door hardware or springs,contact a Genie
FactoryAuthorized De aler for service,orcontact Customer Serviceat 1-800-3S-GENIE.
®
Door will only run open Check Safe-T-Beam System asdetailed in the Safe-T-Beam®SystemSelf-diagnosticTroubleshooting Chart
®
(seeSafe-T-Beam SystemSelf-diagnosticTroubleshooting Sectionon page 26).
. CheckCloseLimit Switch for a short circuit and for proper wiring.
. CheckCloseForceadjustment (seeSetLimit Switchesand ForceControls on page 20). Adjust as needed.
Lights will not turn off . DisconnectWires connecting Wall Console to Power Head(seeWallConsole Installation on page 18).
Checktheir condition and either replace or reconnect.
. Until a replacement Wall Consolecan be obtained, disconnectWall Consoleand useonly Remote Controls
or WirelessKeypadto operate Opener.
Door starts up, but stops Check (ensure) that garage door and Opener are in good repair,properly lubricated, and properly
before it is balanced as detailed in Maintenance Section.
corn pletely open . W _ H' : If you suspecta problem with the garage door hardware or springs,contact a Genie
FactoryAuthorized De aler for service,orcontact Customer Serviceat 1-800-3S-GENIE.
. CheckOpen Limit Switch for a short circuit and for proper wiring.
. CheckOpen Forceadjustment (seeSet Limit Switchesand ForceControls on page20). Adjust as needed.
Operator runs,but door EnsureMagnetic CarriageAssembly is engaged to RailDrive Screw(seeInstall Magnetic CarriageAssembly
does not move onto Railson page 10).
. CheckForceadjustment (seeSet Limit Switchesand ForceControls on page 20).Adjust as needed.
. Checkthat all sectionsof RailDrive Screwareturning when Motor runs. If not:
- Checkcondition (not cracked,split,or broken) and placement of Coupler. Replaceas needed.
- Checkcondition (not cracked,split,or broken) and placement of Collar and Clip. Replacethem
as needed.
Wall ConsoleVacation . EnsureMagnetic CarriageAssembly is in contact with Close Limit Switch.
Lockfunction does . Checkwhen door isfully closed,that Carriageactivates Close Limit Switch. If not,adjust position of Close
not work Limit Switch (Seepage 19).