Genie 3531835447 Garage Door Opener User Manual


 
See Status Light on Figure38, page 22)
You See
1 BLINK,
Pause
(Repeat)
2 BLINKS,
Pause
(Repeat)
3 BLINKS,
Pause
(Repeat)
4 BLINKS,
Pause
(Repeat)
SBLINKS,
Pause
6 BLINKS,
Pause
7 BLINKS,
Pause
Problem
Motor Drive
Board
Normal
operation
restored
If the problem
recurs
Operation not
restored
Controller
Board
Interrupt
Opener
Overheated
or
Force Settings
Incorrect
Safe-T-Beam ®
Malfunction
Wall Console
does not work
Limit Switches
not working
What to Do
. Reset Opener--unplug (or disconnect power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console.
. First Cycle will run at slow speed.
Reference
. Check door condition. NOTE:This Opener is equipped with an
automatic garage door balance detection system. An improperly
balanced door, damaged or worn counter-balance spring, binding
door hardware or rollers may result in a "ONE-BLINK" signal,
Contact Customer Service for further assistance.
. Checkdoor condition.
. Have a Genie Factory Authorized Dealer check:
- Fuse on Motor Drive Board.
- Ribbon Cable on Motor Drive Board is properly inserted into
Connector on Controller Board.
. Contact Customer service for further service.
. Reset Opener -- unplug (or disconnect power), wait S seconds, plug
back in (reapply power), and activate from Wall Console.
. Have a Genie Factory Authorized Dealer check that Ribbon Cable on
Motor Board is properly inserted into connector on Controller Board.
. Contact Customer Service for further assistance.
. Do not unplug or disconnect power from Opener.Wait 10 minutes
for internal clock to provide additional cycles. Cycles are restored
at a rate of S cycles per 10 minutes of rest.
. Check Force Settings. NOTE: Force Settings are not pre-set at factory.
. Checkdoor condition.
. Contact Customer service for further assistance.
. Check Safe-T-Beam ® Self-diagnostic System. NOTE: Safe-T-Beam ®
System must be installed and operational to enable door to close,
Contact Customer Service for further assistance.
. Check Wall Console Wiring for shorts, tight Staples, or pinched Wires.
. Check Wiring Connections at Power Head and Wall Console.
Contact Customer Service for further assistance
. Check Limit Switch Wire connections to Terminals on Power Head.
. Check for shorted or pinched Wires under Limit Switch Brackets.
. Contact Customer Service for further assistance.
. Vacation Locking Switch on Wall Control is in"Lock" mode.
Unlock switch.
. Contact Customer Service for further assistance.
See Door
Safety Guide
1. See page 3.
2. See door
Safety Guide
1. See page 20.
2. See Door
See page 16.
See page 18.
See page 20.
8 BLINKS, Wall Console See page 18
Pause locked
(Repeat)
NOTE
The status LED Indicator Light islocated under the Lens Cover.The Green LED light will turn ON, then OFF when
power is applied to the Opener. If LEDstays ON, have a Genie Factory Authorized Dealer check the Controller
Board, or call Customer Service at 1-800-35-GENIE.
If Safe-T-Beam® problems exists, the door can be closed electrically by holding the Wall Console Button down
until door isfully closed.
The Remote Controls and Wireless Keypad will not work without a working Safe-T-Beam® System.