Franklin TS-TPI Water Pump User Manual


 
TROUBLESHOOTING Page 8-3
8
TS-TPI Installation and Wiring Guide
STP-SCI or STP-SC
HEXVALUE DECIMALVALUE FAULT CODE DESCRIPTIONS
0 0 No Fault
1 1 Under Load (Dry Run or Tank Empty)
2 2 Under Voltage (low / fluctuating input voltage)
3 3 Locked Rotor
4 4 Open Circuit (or Locked Rotor or Relay Fault)
8 8 Uncalibrated (new installation)
9 9 Extended Run (continuous hook signal
greater than 60 minutes without pumping
product)
A 10 Relay Fault (relay contact failure)
ControllerController
ControllerController
Controller
STP-SCIII
HEXVALUE DECIMALVALUE FAULT CODE DESCRIPTIONS
0 0 No Fault
1 1 Under Load (Dry Run or Tank Empty)
2 2 Under Voltage (low / fluctuating input voltage)
3 3 Over Load / Locked Rotor
4 4 Open Circuit (or Locked Rotor or Relay Fault)
8 8 Uncalibrated (new installation)
9 9 Extended Run (continuous hook signal
greater than 60 minutes without pumping
product)
A 10 Relay Fault (relay contact failure)
B 11 L2 Open (L2 input leg not connected)
C 12 Over Voltage (voltage too high)
D 13 Voltage Unbalance Warning
E 14 Load Unbalance Warning
MagVFC
HEXVALUE DECIMALVALUE FAULT CODE DESCRIPTIONS
0 0 No Fault
1 1 Under Load (Dry Run or Tank Empty)
2 2 Under Voltage (low / fluctuating input voltage)
3 3 Locked Up (rotor locked)
4 4 Open Circuit
5 5 Ripple (capacitor bank bad)
6 6 Shorted (short circuit in connections)
7 7 Over Temp (excessive operating temperature)
8 8 Over Speed (excessive operating speed)
9 9 Extended Run
A 10 Locked rotor while PMA is running
E 14 Short Circuit (upper rail short)
Controller Type: VFCIVController Type: VFCIV
Controller Type: VFCIVController Type: VFCIV
Controller Type: VFCIV