TABLE 9: BURNER SPECIFICATIONS
Beckett AFG
Boiler Model
Firing Rate
GPH
Settings Nozzle
3
Pump
Pressure
Head
(Setting)
Air
Shutter
Air
Band
GPH x Angle Type
2
Shipped
1
CL3-091
0.65 L1 8 0 0.55 x 70B (Delavan)
p Loose
140
CL3-105 0.75 L1 6 0 0.65 x 45B (Hago)
p Loose
140
p CL3-140
1.00 L1 10 1 0.85 x 45B (Hago) Installed 140
CL4-126 0.90 L1 7 0 0.75 x 45B (Delavan) Installed 140
CL4-175 1.25 V1(0) 10 1 1.00 x 45B (Hago)
Loose
175
CL4-210
1.50 V1(0) 10 2 1.10 x 45B (Hago) Installed 175
CL5-168 1.20 V1(2) 10 0 0.90 x 45B (Hago)
l Loose
175
l CL5-245
1.75 V1(3) 7 3 1.35 x 45B (Hago) Installed 175
CL5-280 2.00 V1(4) 10 3 1.50 x 45B (Hago) Installed 175
Carlin Burner
Boiler Model
Firing Rate
GPH
Burner
Model
Settings Nozzle
3
Pump
Pressure
Head
Bar
Air
Band
GPH x Angle Type
2
Shipped
CL3-091 0.65
EZ-1HP
0.50 0.55 0.55 x 70B (Delavan)
p Loose
150
CL3-105 0.75 0.60/0.65 0.60 0.60 x 60ES (Hago)
p Loose
150
p CL3-140
1.00 0.85/1.00 0.75 0.85 x 60B (Hago) Installed 150
CL4-126 0.90 0.75 0.75 0.75 x 60A (Delavan)
Loose
150
CL4-175 1.25 0.85/1.00 1.00-1.10 1.00 x 60A (Delavan)
Loose
150
CL4-210
1.50 1.10/1.25 1.25-1.35 1.25 x 60B (Hago) Installed 150
CL5-168 1.20 0.85/1.00 0.90 1.00 x 60B (Hago) Installed 150
CL5-245 1.75 EZ-2HP 1.50 1.75 1.50 x 60A (Delavan) Installed 150
1
Beckett low ring rate bafe required on CL3-091 (0.65 GPH) application only; shipped loose with nozzle.
2
Nozzle(s) for alternate boiler model ring rate(s) are shipped loose in bag attached to the
burner designated by corresponding symbol, i.e. (p) = CL3-140.
3
Single stage fuel pump is standard, two stage fuel pump is optional. Burner manufacturer has preset
single stage fuel pump to settings shown in table above.