Energy Tech Laboratories F3 Boiler User Manual


 
34
VI. Boiler Cleaning
Figure 28: Cleaning of Boiler Flueways
A. CLEAN THE FLUEWAYS (See Figure 28).
1. Disconnect oil line(s) and remove burner and burner
mounting plate. See Figures 1A thru 1D.
2. Lay protective cloth or plastic over combustion
chamber blanket.
3. Remove the smokepipe as necessary to gain access
to the boiler canopy.
4. Remove the jacket top panels.
5. Remove the canopy being careful not to damage the
cerafelt gasket.
6. Usinga1¼”diameterwireorbrebristlebrush
(30”handle)cleantheueways.Brushfromthetop
using diagonal strokes for best results. DO NOT
allow brush to strike the target wall or liner in the
chamber.
B. CLEANTOPOFBOILERSECTIONS.
1. Brushandvacuumthetopsoftheboilersections.
C. CLEANTHEFIREBOX.
1. Usingwireorbrebristlebrush,cleancrown
of boiler and inside of water legs. DO NOT
allow brush to strike target wall or blanket in the
combustion chamber.
D. AFTERCLEANING,removeprotectiveclothwith
debrisandvacuumasnecessary,butbecarefulnot
todamageblanket.Inspecttargetwall,combustion
chamber blanket and burner mounting plate insulation
forsignsofdamage.Ifdamaged,replaceasneeded.
E. REASSEMBLEBOILER.
CAUTION: Donotstarttheburnerunlesscanopy,
smokepipe and burner swing door are secured in place.
1. Installthecanopytakingcaretoalignthegaskets
withoutblockingtheueways.Ifgasketisdamaged,
replace as needed.
2. Close and secure burner swing door to front section
with fasteners.
3. Reconnect oil line(s).
4. Reinstall Top Panels and secure with sheet metal
screws.
5. Reinstall smokepipe on canopy and secure to collar
with sheet metal screws.
WARNING
All boiler cleaning must be completed with burner service switch turned off.
WARNING
The boiler must be connected to an approved
chimney in good condition. Serious property
damage could result if the boiler is connected
to a dirty or inadequate chimney. The interior of
the chimney ue must be inspected and cleaned
before the start of the heating season and
should be inspected periodically throughout the
heating season for any obstructions. A clean and
unobstructed chimney ue is necessary to allow
noxious fumes that could cause injury or loss
of life to vent safely and will contribute toward
maintaining the boiler's efciency.