Enviro C-10794 Indoor Fireplace User Manual


 
8
Electronic
ignition module
Maintenance And Service
ROUTINE MAINTENANCE:
At least once a year, run through the following procedures to ensure the system is clean and working
properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not
blocked by anything. The pilot ame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufcient to allow access for maintenance and service
Warning: Failure to position the parts in accordance with this manual, or failure to use only parts
specically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a
qualied agency.
CLEANING THE GLASS:
When the replace has cooled, remove the face of the replace along with the glass. See MAINTENANCE
AND SERVICE - GLASS DOOR REMOVAL. Check the gasket material on the back of the glass, making sure that it
is attached and intact.
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all
replaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint
curing of the appliance can leave a slight lm behind the glass, a temporary problem. The glass will need
cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth; abrasive
cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass
should require cleaning no more than two or three times a season. Do not clean the glass when it is
hot.
CLEANING THE FIREBOX:
Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and
place on a paper towel. Vacuum the bottom of the rebox thoroughly. Carefully clean any dust off the
logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or
severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large
amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers
as in the LOG SET AND EMBER INSTALLATION section. If new/more embers and rock wool are required, contact
your nearest ENVIRO dealer.
CHANGE BATTERY IN IGNITION MODULE:
If the unit does not spark when lighting, the battery in the
electronic ignition could need replacing.
Located on the left hand rear corner of the unit is a small
rectangular hole. Located here is the electronic ignition module
(see Figure 6). Remove the battery cover, located on the left side
of the module, and replace the AA battery.
Reinstall the battery cover and check for spark by depressing the
pilot knob located on the control panel.
Figure 6: Electronic Ignition Module
Location.