Enviro C-10794 Indoor Fireplace User Manual


 
36
Figure 57: Top brick panel in place, screws shown. Figure 58: Back brick panel in place.
Figure 59: Side brick panels in place.
Figure 56: Brick panel bracket, slots shown.
1. Remove the two (2) screws from the
rear of the bafe, use a ” socket
or a at head screwdriver. Place the
provided brick bracket (Figure 56) at
the rear of the bafe with the slots
over the screw holes (see Figure 57).
Insert two (2) of the provided screws
into the two (2) holes along the
bottom of the bafe.
2. Remove the two (2) screws from the front of the
bafe. Slide the top brick panel into the bottom
bracket and place the other brick bracket over the top
of the panel and line up the slots on the bracket with
the holes at the top of the bafe. Use two (2) of the
provided screws to hold the bracket in place. Ensure
the top panel is centered before tightening the four
(4) screws completely (refer to Figure 57).
3. Slide the bottom brick panel into place under/behind
the top panel bracket, the notched side is to rest on
the rebox bottom. The panel should rest ush with
the back of the rebox (refer to Figure 58).
4. Slide each side brick panel into place along the sides
of the rebox. The panels should rest ush with the
back panel and the sides of the rebox (refer to
Figure 59).
Secondary Installation
INSTALLATION OF PANEL SET:
Do not install when the unit is hot.
The brick panel set is fragile. Handle panels with care and avoid knocking them on the
placement pins or any other object.