Enviro C-10794 Indoor Fireplace User Manual


 
5
Specifications
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
DIMENSIONS:
16
5
/8"
(42.2cm)
25 "
(65.3cm)
25 "
(65.4cm)
27"
(68.6cm)
25 "
(65.3cm)
17
1
/8"
(43.5cm)
15 "
(40.0cm)
27"
(68.5cm)
15
1
/8"
(39.0cm)
Floor to center of flue
REAR VENT
23” (59.7 cm)
CLEARANCES TO COMBUSTIBLES:
A. Sidewall to unit 11 inches (27.9 cm)
B. Backwall to unit 2.5 inches (6.35 cm)
C. Corner to unit 2.5 inches (6.35 cm)
D. Ceiling 60 inches above oor (152.4 cm)
E. Floor (hard wood and linoleum) 0 inches
Note: When installing on a carpeted surfaces a non-
combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width 48 inches (121.9 cm)
Height 60 inches (152.4 cm)
Depth (max) 24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
Figure 1: Westport Exterior Dimensions.

 
 


 
 
Figure 2: Clearances to combustibles.