Specifications
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
DIMENSIONS:
16
5
/8"
(42.2cm)
25 "
(65.3cm)
25 "
(65.4cm)
27"
(68.6cm)
25 "
(65.3cm)
17
1
/8"
(43.5cm)
15 "
(40.0cm)
27"
(68.5cm)
15
1
/8"
(39.0cm)
Floor to center of flue
REAR VENT
23” (59.7 cm)
CLEARANCES TO COMBUSTIBLES:
A. Sidewall to unit 11 inches (27.9 cm)
B. Backwall to unit 2.5 inches (6.35 cm)
C. Corner to unit 2.5 inches (6.35 cm)
D. Ceiling 60 inches above oor (152.4 cm)
E. Floor (hard wood and linoleum) 0 inches
Note: When installing on a carpeted surfaces a non-
combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width 48 inches (121.9 cm)
Height 60 inches (152.4 cm)
Depth (max) 24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
Figure 1: Westport Exterior Dimensions.
Figure 2: Clearances to combustibles.