Emerson 3-9000-771A Carbon Monoxide Alarm User Manual


 
Daniel 3818 LNG Liquid Ultrasonic Meter Installation Manual Section 3: Electrical installation
3-9000-771 Rev A May 2012
Frequency/Digital outputs 49
Frequency or Digital Outputs (FODO 3) source
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1B Phase
Frequency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency 1A Validity and Flow
Direction)
Digital output 2A is based on Digital output2A content (Frequency 1A Validity and Flow
Direction)
Digital output 2A is based on Digital output 2A content (Frequency 2A Validity and Flow
Direction)
Digital output 2B is based on Digital output 2B content (Frequency 2B Validity and Flow
Direction)
Mode options
Open Collector (requires external excitation supply voltage and pull-up resistor)
TTL (internally powered by the meter 0-5 VDC signal)
Channel B Phase options:
Lag forward, Lead reverse (Phase B lags Phase A while reporting forward flow, leads Phase
A while reporting reverse flow)
Lead forward, Lag reverse (Phase B leads Phase A while reporting forward flow, lags Phase
A while reporting reverse flow)
Phase A and Phase B output (based on flow direction)
Reverse flow - output only reports flow in the reverse direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
Forward flow - output only reports flow in the forward direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
Absolute - output reports flow in both directions. For frequency outputs, Phase B of the
output is 90 degrees out of phase with Phase A.
Bidirectional - output reports flow on Phase A only in the forward direction and on Phase
B only in the reverse direction.
Maximum frequency for the frequency outputs
1000Hz
5000Hz