Eaton Electrical PVE12 Heat Pump User Manual


 
33
Model
Compensator
Pressure
Setting Psig
Table 9. Load sensing compensator adjustment range.
Lockwire
Standby
Pressure
P2
P @
USgpm
(P2-P1)
P @ Compensator
Cracking
Pressure (P2-P1)
PVE19*-*-**-CV-10
PVE19*-*-**-CVP-12
PVE19*-*-**-CVPC-12
PVE12*-*-**-C**VPD41
PVE21*-*-**-CV-10
PVE21*-*-**-CVP-12
PVE21*-*-**-CVPC-12
Not Applicable
Not Applicable
3000
2700
3000
2700
Yes
Yes
Yes
250
psi
Max.
550
psi
Max.
160 psi
± 20 psi
4 USgpm
+20
30
+20
30
+20
30
160 psi
360 psi
350 psi
PVE12*-*-**-C**VPC24
PVE12*-*-**-C**VP11
3000
3000
3000 Yes
Yes
250
psi
Max.
900
psi
Max.
500
psi
Max.
+20
30
600 psi
+20
30
160 psi
350 psi
± 25 psi
4 USgpm
600 psi
± 50 psi
4 USgpm
160 psi
± 20 psi
6.5 USgpm
350 psi
± 25 psi
6.5 USgpm
Form No. 00-000 Copyright Eaton Corporation, 0000
All rights reserved.
Printed in U.S.A
Eaton Hydraulics
15151 Highway 5
Eden Prairie, MN 55344
Telephone: 612 937-7254
Fax: 612 937-7130
www.eatonhydraulics.com
46 New Lane, Havant
Hampshire PO9 2NB
England
Telephone: (44) 170-548-6451
Fax: (44) 170-548-7110