WARNING: This appliance
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
ELECTRICAL HOOKUP
This fireplace normally operates under 120
VAC/60 Hz line voltage. The electrical cord sup
-
plied with your fireplace is five feet in length. You
must locate fireplace within reach of a 120 volt
grounded electrical outlet. If not, you must install
an electrical outlet within reach of the fireplace
power cord. The GA3555 outlet accessory may
be used for built-in applications.
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
INSTALLATION
Continued
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom
Right Sides and Rear
0" 16" 0"
Carefully follow the instructions below. This will
ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 5.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3 1/2" from the wall. This combus-
tible material must be 4" from the side of the
fireplace cabinet (see Figure 5).
B. Clearances from the top of the fireplace open
-
ing to the ceiling should not be less than 42
inches.
Figure 5 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
INSTALLATION SEQUENCE
After unpacking fireplace (see Unpacking, page 4),
we suggest that you install your fireplace system
in the following sequence:
1.
Removal of fireplace floor assembly (required)
2.
Electrical connections for power cord (required)
3. Relocating wall switch (optional)
4. Installing blower accessory (optional)
5.
Connecting fireplace to gas supply (required)
6. Checking gas connections (required)
7. Firebox installation, conventional or built-in
(required)
8. Installing brass perimeter trim (optional)
9. Installing fireplace hood (required)
10. Installing logs (required)
11. Installing fireplace screen (required)
Use the following instructions to complete
each step.
REMOVING FIREPLACE SCREEN
AND FLOOR ASSEMBLY
NOTICE: Shutoff gas supply
and disconnect heater from gas
supply if installing blower into
previously installed fireplace.
Contact a qualified service per-
son to do this.
1. Remove fireplace screen. Remove two screws
that hold fireplace screen in place for shipping.
These screws are located near top of screen.
Discard screws. Lift fireplace screen up and
pull out to remove.
2. If logs are installed, carefully remove the logs
and set aside, noting the properly mounted
location of each.