NORMAL LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this heater with the fireplace
screen in place. Make sure fire
-
place screen is in place before
running heater.
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Open
damper or window to vent smell.
This will only last a few hours.
1. STOP! Read the safety information on
page 25.
2. Make sure equipment shutoff valve is
fully open.
3. Wait five (5) minutes to clear out any gas.
Smell for gas around heater and near floor. If
you smell gas, STOP! Follow “B” on page 25.
If you donʼt smell gas, go to the next step.
A. Using Supplied Wall Switch Assembly
1. Set manual ignition bypass switch on the
control panel to the OFF position (auto
-
matic ignition position).
2. Press ON/OFF button. Hold for 6 seconds.
Gas valve will open and electronic ignition
will begin sparking to light pilot. LED will
light. Note: You may be running this heater
for the first time after connecting to gas sup
-
ply or at the start of your heating season.
If so, the ON/OFF button may need to be
pressed again. This will allow air to bleed
from gas system. If several attempts to light
pilot fail, contact a qualified service person
or gas supplier for repairs. Until repairs
are made, light and operate manually (see
Manual Lighting Instructions for Electric
Power Outage, page 27).
3. When pilot flame is lit, the thermocouple is
heated by the flame. When thermocouple
becomes hot (5 to 15 seconds), main burner
will automatically light on high flame.
4. To lower flame, push HI/LO button on wall
switch once.
Note: This fireplace does not
have a pilot-only mode.
OPERATING FIREPLACE
Continued
Figure 47 - Control Locations
Manual Ignition Bypass Switch
(Up is for Remote Control)
ON/OFF
Button
HI/LO
Button
Wall
Switch
Assembly
LED
Automatic
Ignitor
Electrode
Figure 48 - Pilot (Natural Gas)
Manual Ignitor
Electrode
Figure 49 - Pilot (Propane/LP Gas)
Automatic
Ignitor
Electrode
Pilot
Burner
Manual Ignitor
Electrode
Pilot
Burner
B. Using Hand-Held Wireless Remote
Control
1. Set manual ignition bypass switch on
control panel to OFF position (automatic
ignition position).
2. Wait five (5) minutes to clear out any gas.
Smell for gas around heater and near floor.
If you smell gas, STOP! Follow “B” on page
25, column 2. If you donʼt smell gas, go to
the next step.
3. Point remote control toward the lower
front of fireplace and push both buttons
at the same time. Hold for 6 seconds. The
gas valve will open and electronic igni
-
tion will begin sparking to light the pilot.
Note: You will be able to hear a clicking
sound during this process. LED on wall
switch will light.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.