Desa CGEFP33PRB, CGEFP33NRB, EFP33PRB, EFP33NRB Indoor Fireplace User Manual


 
www.desatech.com
111245-01B
14
9. Check to make sure that all electrical cords
are completely clear of the blower wheel
and that there are no other foreign objects in
blower wheel. Turn blower on and check for
operation. Turn blower off by rotating knob
fully counterclockwise before continuing.
CAUTION: Never touch the
blower wheel while in operation.
10. Peel off backing paper and stick supplied
wiring diagram decal near center of firebox
bottom (Figure 17).
11. If gas connections have been made and
checked, replace fireplace floor assembly.
Feed flexible gas supply line into fireplace
base area while replacing fireplace floor as
-
sembly. Make sure the entire flexible gas line
is in fireplace base area.
IMPORTANT: Do not pick up fireplace floor
assembly by burners. This could damage
burners. Only handle base by grates. Note:
Be careful of all wires and components on
underside of floor assembly.
12. Reattach fireplace floor assembly with
screws removed in step 3 of Removing Fire
-
place Screen and Floor Assembly, page 9.
Note: Discard the remaining hardware items.
After assembly, make sure all wires are com
-
pletely clear of blower wheel.
13. Install logs (see Installing Logs, page 24 and
fireplace screen (see Installing Screen, page
25).
INSTALLATION
Continued
V
a
r
i
a
b
l
e
F
a
n
S
w
i
t
c
h
W
h
it
e
W
h
it
e
B
l
a
c
k
G
r
e
e
n
O
n
1
1
0
/
1
1
5
V
.A
.
C
.
Bl
ower
Moto
r
B
l
a
c
k
B
l
a
c
k
B
l
a
c
k
O
f
f
Wiring
Diagram
Figure 17 - Location of Wiring Diagram
Decal 3" from Blower
Operating the Blower
Light your gas appliance with the blower off. After
about 15 minutes, turn the blower on to deliver
heated air at the top louvers. The blower features
a variable control which allows you to select the
speed you desire. Note: Periodically check the
louvers of the firebox and remove any dust, dirt
or other obstructions.
Variable
Fan Switch
White
White
Black
Green
On
11
0/115
V.
A.C.
Blower
Motor
Black
Black
Black
Off
Plastic
Bushing
Right Floor
Support Bracket
Figure 16 - Installing Plastic Bushing for
Power Cord
WARNING: Failure to position
the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in
damage or personal injury.
WARNING: A qualified service
person must connect fireplace
to gas supply. Follow all local
codes.