Desa CD36TN-M Indoor Fireplace User Manual


 
www.desatech.com
118531-01A 5
LOCAL CODES
Install and use replace with care. Follow all local
codes. In the absence to local codes, use the cur-
rent National Fuel Gas Code ANSI Z223.1/NFPA
54* (USA) or the current CSA-B149.1 Installation
Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
These are a few facts that can help you understand
and enjoy your direct-vent replace:
The dedicated top vent for this replace is suited
for any application where height is necessary
to terminate the venting system either through
the roof (vertical) or to gain sufcient height
and offset to vent to an outside/exterior wall
(horizontal).
The vent pipe installation is very important to
allow for proper operation. You must select the
appropriate vent kits and components for your
application and follow the venting instructions
to plan your installation.
This replace may be installed in any room pro-
vided that all rules of the housing authority and
these installation instructions are followed.
This replace is equipped with a millivolt gas
control system that does not require electricity to
operate. A piezo ignitor is provided to light the
pilot without using matches or lighters.
This model can accept an optional circulating
air blower when 120 VAC connection is sup-
plied. If you plan to install an optional blower,
do not forget to wire the replace outlet when
framing.
Each time you turn on your replace, you may
notice some amount of condensation on the in-
side of the replace glass. This is normal and will
disappear after 10-20 minutes of operation.
Your direct-vent gas replace system (replace
and venting) is a balanced and sealed gas oper-
ating unit. It is highly efcient because it uses
outside air for combustion while independently
heating the indoor air.
Figure 2 - Common Fireplace Locations
Flush with
a wall
Through exterior wall
enclosed in a chase
Corner
installation
PRE-INSTALLATION
PREPARATION
LOCATION AND SPACE
REQUIREMENTS
Determine the safest and most efcient location for
your DESA/Vexar direct-vent replace. Make sure
that rafters and wall studs are not in the way of the
venting system. Choose a location where the heat
output is not affected by drafts, air conditioning
ducts, windows or doors. Figure 2 shows some
common locations. Be aware of all restrictions and
precautions before deciding the exact location for
your replace and termination cap.
When deciding the location of your replace,
follow these rules:
Do not connect this replace venting to a chim-
ney ue serving a separate solid fuel burning
replace or appliance.
Due to high temperatures, do not locate this
replace in high trafc areas, windy or drafty
areas or near furniture or draperies.
Proper clearances must be maintained.
If your replace is to be installed directly on
carpeting, vinyl tile or any combustible material
other than wood, it must be installed on a metal
or wood panel extending the full width and depth
of the replace. See Figure 3, page 6.
Your replace is designed to be used in zero
clearance installations. Wall or framing material
can be placed directly against any exterior sur-
face on the back, sides or top of your replace,
except where standoff spacers are integrally
attached. If standoff spacers are attached to your
replace, these spacers can be placed directly
against wall or framing material. See framing
details on page 6.
If you plan on installing a television or enter-
tainment center recessed above your replace, it
is recommended that you maintain a minimum
18" above top of louver opening.