Dell E30S Vacuum Cleaner User Manual


 
Connectors
Internal
USB One 9-pin, USB 3.0-compliant
Internal Dual SD Module Two optional flash memory card slots with the
internal SD module
NOTE: One card slot is dedicated for
redundancy.
Video
Video type Integrated Matrox G200 with iDRAC8
Video memory 16 MB shared with iDRAC8 application memory
Expanded Operating Temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.
< 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew
point.
NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to 5 °C or up to 40 °C for a
maximum of 10% of its annual operating
hours.
For temperatures between 35 °C and 40 °C, de-
rate maximum allowable dry bulb temperature by
1 °C per 175 m above 950 m (1 °F per 319 ft).
< 1% of annual operating hours –5 °C to 45 °C at 5% to 90% RH with 26 °C dew
point.
NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to –5 °C or up to 45 °C for a
maximum of 1% of its annual operating hours.
For temperatures between 40 °C and 45 °C, de-
rate maximum allowable dry bulb temperature by
1 °C per 125 m above 950 m (1 °F per 228 ft).
Expanded Operating Temperature Restrictions
For low-power CPUs (55 W/ 65 W), both the
internal cooling fan and the external cooling
fan need to be installed.
The operating temperature specified is for a
maximum altitude of 3048 m (10,000 ft).
GPU card is not supported.
LRDIMM is not supported.
175