Brother LK3-B448E Sewing Machine User Manual


 
LK3-B448E MARKII/BA-16
15. Changing special functions using the memory switches
64
memo-11 - memo-13
memo-19
memo-1A
memo-1b
memo-14
memo-15
memo-16
memo-17
memo-18
memo-1F
Motion when set to ON
Presser position errors are not detected.
Needle up stop position errors are not detected.
Presser can be moved up and down before the home position is detected.
(Normally the presser cannot be moved up and down until after the home position has been
detected.)
Solenoid wiper can be used (available as an option).
Needle cooler output is enabled. (Needle cooler is available by special order.)
Thread take-up device is not operated at the sewing end.
Thread take-up device operates one stitch before the sewing end.
Thread is not trimmed when an emergency stop occurs during sewing. (EMERGENCY STOP
switch is available as an option.)
Switch
memo-1c
memo-1d
memo-1E
Errors can be reset using the EMERGENCY STOP switch. (EMERGENCY STOP switch is
available as an option.)
memo-10 The optional emergency stop switch can be used.
memo-20
memo-21
Motion when set to ON
Machine head from previous B430E series is used. (Only the operation panel and box are Mark
II.)
Rotating-type thread breakage detector operates. (Device is available by special order.)
Switch
memo-22
During thread breakage detection, sensitivity is decreased from 8 to 14 stitches at the sewing
start. (Sensitivity during sewing is three stitches.)
memo-23
When DIP switch A-8 is simultaneously ON, setting values changed using the operation panel are
ignored.
memo-24 - memo-2F
memo-30
memo-31
memo-32
memo-33
memo-34
memo-35
memo-36
memo-37
memo-38
memo-39
memo-3A
memo-3b
memo-3c
memo-3d
memo-3E
memo-3F
memo-40
-
memo-4F
Possible setting range
0 - 30
0 - 30
12 - 27
1 - 15
0 - 5
3 - 9
0 - 99
1 - 20
1 - 20
1 - 20
1 - 20
1 - 20
Units
mm
mm
x 100rpm
x 7.5°
Needle
x 100rpm
x10ms
x 7.5°
x 7.5°
x 7.5°
x 7.5°
x 7.5°
Initial value
7
7
25
10
1
4
0
10
10
1
1
1
Explanation
Limits the maximum area in the horizontal direction (X)
(Limited to 6.4 mm when settings have been initialized.)
Limits the maximum area in the vertical direction (Y)
(Limited to 6.4 mm when settings have been initialized.)
Changes the maximum sewing speed.
Changes the feed timing
1 (Fast) ¨10 (Standard) Æ15 (Slow)
The sewing speed at the sewing start is 400 rpm for the
specified number of stiches.
Changes the sewing start speed specified by memo-34.
Timer for controlling timing during continuous operation
Changes the feed timing one stitch before the sewing end.
1 (Fast) ¨10 (Standard)Æ20 (Slow)
Changes the feed timing two stitches before the sewing
end.
Changes the feed timing for the third stitch at the sewing start.
1 (Fast) ¨10 (Standard) Æ20 (Slow)
Changes the feed timing for the second stitch at the sewing start.
Changes the feed timing for the first stitch at the sewing start.
Switch
Memory switches 10 - 1F
Memory switches 20 - 2F
Memory switches 30 - 4F
30 to 4F are set by entering two-digit values.