Brother DH4-B980 Sewing Machine User Manual


 
7. SEWING
RH-9800
35
7-5. Using the production counter
The production counter is initially set to the counting up from zero method. It can display up to a maximum count of 9999.
* If DIP switch No. 4 inside the front panel is set to OFF, the counting up from zero method will be used. If DIP switch
No. 4 is set to ON, the counting down to zero method will be used.
Displaying the production counter
1. Press the MODE button (1) to switch to automatic
mode.
* The production counter will appear in the front
panel display (J).
Resetting the production counter
Counting up from zero method
1. Press the MODE button (1) to switch to automatic mode.
2. Press the ENTER button (N).
* The units digit will start flashing in the display.
3. Press the RESET button (2).
* The units digit will change to "0" and the counter
value will be reset to "0".
Counting down to zero method
1. Press the MODE button (1) to switch to automatic mode.
2. Press the ENTER button (N).
* The units digit will start flashing in the display.
3. Press the "Up" button (L) or the "Down" button (K) to
set the value for the units column, and then press the
ENTER button (N).
Repeat this step for the tens, hundreds and thousands
columns.
* The production counter function can be stopped by
setting counter to “0000”.
* When the thousands column has been set, the
machine will return to normal automatic mode.
Note: If the counting down to zero method is used, further sewing will not be possible when the production counter
reaches "0", so a number greater than zero should always be set. The production counter can be returned to
the initial setting value simply by pressing the ENTER button (N).
* If you would like to change the production counter setting due to sewing errors, use the counting down to zero
setting procedure to set the production counter.
Standard position (Counting up from zero method)
Reset position (Counting down to zero method)
1168Q
1019Q
(1)
(J)
1169Q
1170Q
(N)
(2)
1171Q
1172Q
(K)
(L)
(N)