Bacharach 24-9351 Carbon Monoxide Alarm User Manual


 
PCA
Instruction 24-9351
4-22
Operation
4.16 Display Mode Setup Screen
(For PCA Models 30, 35, 60 & 65)
SETUP
DISPLAY «CO NX
CU NU
The Display Setup Screen is displayed by repeatedly pressing the MENU
key from the Combustion Test Screen. Use this screen to select whether
the Combustion Test Screen will display the measured values of Carbon
Monoxide and Nitric Oxide (CO and NX), or the calculated values of these
gases (CU and NU) referenced to 0% Oxygen.
To setup the display, first use the st keys to move the cursor (z) in front
of either CO NX (measured values), or CU NU (calculated values), and
then press the key.
Front Panel Key Functions:
Move cursor (z) up
Move cursor (z) down
Select Display Mode
Go to Combustion Test Screen
Go to Time/Date Setup Screen