Integrated control module will automatically attempt to reset from lockout after one hour.
TRTR
TRTR
TR
OUBLESHOUBLESH
OUBLESHOUBLESH
OUBLESH
OOOO
OOOO
OO
TINTIN
TINTIN
TIN
G CHARG CHAR
G CHARG CHAR
G CHAR
TT
TT
T
Furnace lockout due
to an excessive
number of ignition
“retries” (3 total)
1
.
Locate and correct gas
interruption.
Check front cover
pressure switch
operation (hose, wiring,
contact operation).
Correct if necessary.
Replace or realign
igniter.
Check flame sense
signal. Sand sensor if
coated and/or oxidized.
Check flue piping for
blockage, proper
length, elbows, and
termination.
Verify proper induced
draft blower perfor-
mance.
Turn power
OFF prior to
repair.
Igniter is
fragile, handle
with care.
Sand flame
sensor with
emery cloth.
See “Vent/Flue
Pipe” section
for piping
details.
Furnace fails to operate.
Integrated control
module diagnostic LED
is flashing ONE (1) flash.
1
1 FLASH
Failure to establish flame.
Cause may be no gas to
burners, front cover
pressure switch stuck
open, bad igniter or igniter
alignment, improper
orifices, or coated/oxidized
or improperly connected
flame sensor.
Loss of flame after
establishment. Cause may
be interrupted gas supply,
lazy burner flames
(improper gas pressure or
restriction in flue and/or
combustion air piping),
front cover pressure
switch opening, or
improper induced draft
blower performance.
Pressure switch
circuit is closed.
Induced draft
blower is not
operating.
Replace induced draft
blower pressure
switch.
Repair short.
Turn power OFF
prior to repair.
Replace pressure
switch with proper
replacement part.
Furnace fails to operate.
Integrated control
module diagnostic LED
is flashing TWO (2)
flashes.
2
2 FLASHES
Induced draft blower
pressure switch contacts
sticking.
Shorts in pressure switch
circuit.
Inspect pressure
switch hose. Repair, if
necessary,
Inspect flue and/or inlet
air piping for blockage,
proper length, elbows,
and termination. Check
drain system. Correct
as necessary.
Correct pressure
switch setpoint or
contact motion.
Tighten or correct
wiring connection.
Pressure switch hose
blocked, pinched or
connected improperly.
Blocked flue and/or inlet air
pipe, blocked drain system,
or weak induced draft
blower.
Incorrect pressure switch
setpoint or malfunctioning
switch contacts.
Loose or improperly
connected wiring.
Pressure switch
circuit not closed.
Induced draft blower
is operating.
Induced draft blower runs
continuously with no
further furnace operation.
Integrated control
module diagnostic LED
is flashing THREE (3)
flashes.
3
3 FLASHES
Turn power
OFF prior to
repair.
Replace
pressure
switch with
proper
replacement
part.
• Normal operation.
• Normal operation. • None. LED is steady ON.
ON
CONTINUOUS
ON
No 115 volt power to
furnace, or no 24 volt
power to integrated
control module.
Blown fuse or circuit
breaker.
Integrated control
module has an
internal fault.
Manual disconnect switch
OFF, door switch open, or
24 volt wires improperly
connected or loose.
Blown fuse or circuit
breaker.
Integrated control module
has an internal fault.
Assure 115 and 24 volt
power to furnace
integrated control
module.
Check integrated control
module fuse (3A).
Replace if necessary.
Check for possible shorts
in 115 and 24 volt circuits.
Repair as necessary.
Replace bad integrated
control module.
Turn power OFF
prior to repair.
Replace integrated
control module
fuse with 3A
automotive fuse.
Read precautions
in “Electrostatic
Discharge” section
of manual.
Furnace fails to operate.
Integrated control
module diagnostic LED
provides no signal.
NONE
Fault Description(s) Possible Causes Corrective Action Cautions and Notes
Symptoms of Abnormal
Operation
Associated
LED Code
2
• Normal operation.