Aarrow Fires Gas Stove Stove User Manual


 
COMMISSIONING THE STOVE
Refit the glass/glass frame assembly.
Refit the outer body and secure with the locking
levers.
If horizontal flue is used fit the canopy cover
plate. (See page 25 step 1a.)
If top flue is used locate the infill plate (See page
25 step 1b).
Follow the lighting instructions (See pages 32 &
33), light the pilot and check:-
1. The operation of the control
2. The cross lighting of the burner
3. All gas settings can be achieved
FIRE TESTING
Flame failure device testing
Step 1 Ignite the appliance in accordance with page
and run for 60 seconds.
Step 2 Turn the appliance off to extinguish the
pilot, listen for a snap at the control valve. This
should occur within 60 seconds of the pilot flame
being extinguished. The snap sound will be the
magnet disengaging, and thus shutting off the flow
of gas to the pilot and burner.
Spillage T
est
Step 1. Close all doors and windows.
Step 2 Light the appliance and set to the high rate.
Step 3. Allow fire to warm up for 10 minutes.
Step 4. Position the smoke match at the back of the
fire centrally beneath the rear diverter as shown in
Fig 19a.
All of the smoke should be drawn into the fire.
If this does not occur the appliance must be
disconnected and the flue checked.
Step 5. If there is an extractor fan in any room, this
must be turned on and any doors between it and the
fire left open, repeat the spillage test.
Repeated operation of the spillage monitoring
system whereby the OSD (oxygen sensing
device/spillage monitoring system). If their is a
problem with the ODS pilot going out after the
stove has operated satisfactory, this indicates a
possible flue draw problem. Seek expert advise
from a qualified engineer.
Warning: The spillage monitoring system,
consists of a special oxygen sensing device (OSD)
pilot and is a safety feature required by law. It
must not be adjusted or put out of action by the
installer. If the spillage monitoring system or
any of its parts are to be replaced, only original
manufacturers parts must be used.
Fig. 19a
Note: The fire will give off non-toxic fumes when
first used. This is perfectly normal it will disappear
after the first few hours. Once the spillage test is
complete open windows and doors to ventilate the
area.
SELF LEVELING REAR FEET
Once the stove is in position on the hearth, working
on the rear legs, simply loosen the pozi screw and
rotate the inner ‘pear’ shaped adjuster to touch the
hearth. Re-tighten the screw and repeat for the
other side.
Fig. 19b
22 Aarrow Sherborne GSL CF
INSTALLATION INSTRUCTIONS