Aarrow Fires Gas Stove Stove User Manual


 
FITTING THE FLUE SPIGOT AND
BLANKING PLATE
Note: Blanking plate fitted to top flue outlet for
packing
The gas stove is designed so that the flue can be
fitted to either the top or the rear of the appliance.
Fit the flue spigot and blanking plate for either top
or rear flue outlet in accordance with figure 5a or
5b (below).
Lock the blanking hot plate in place by rotating
anti-clockwise and tighten by tapping gently with a
block of wood and mallet. Fit the spigot to the
unused opening in the same way. The units are
sealed by the attached gaskets.
CLOSURE PLATES
If a closure plate is used for sealing off the chimney
or fireplace opening it can be made of metal (e.g.
aluminium sheet) or fireplace board (see figure 6
a/b/c on page 12) however provision must be made
for checking for debris build up. Closure plates
must be sealed to the chimney or fireplace opening
with fire cement, fireproof rope or other suitable
high temperature mastic.
REAR FLUE OPTIONS
Open Hearth (See Figure 6-a page 12)
Fit and seal a ‘T’ section (with debris /soot
collector) directly into the flue spigot. Ensure it
passes through the closure plate by at least 102mm
(4”).
The maximum horizontal section allowed is
350mm.
Provide a minimum vertical height of 600mm of
flue from the height of the rear flue outlet.
Closure Plate (See Figure 6b page 12)
Connect the flue spigot to the rear outlet then
connect a flue extension to the spigot up to a
maximum length of 350mm.
Fit and seal the closure plate into the fireplace
opening.
Position the stove so the flue extension passes
through the hole in the closure plate by at least
50mm.
Ensure all joints are sealed with fire cement or a
suitable high temperature sealant.
TOP FLUE OPTIONS
Top Flue (
See Figure 6c page 12)
Provide a minimum vertical height of 600mm of
flue measured from the top of the appliance.
Position the stove, with flue spigot in place, into
position under the flue and seal the spigot/flue
connection with fire cement or a suitable high
temperature sealant.
It is recommended that a smoke test is performed
inside the stove to ensure that adequate flue draw is
evident after making the flue connection
Aarrow Sherborne GSL CF
11
INSTALLATION INSTRUCTIONS
Fig 5c
Fig. 5a
Fig. 5b