Wayne-Dalton 46 Door User Manual


 
10
Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your
local yellow pages/business listings or go to the Find a Dealer section online at www.wayne-dalton.com
Tools Needed:
HEADROOM REQUIREMENT
DOOR
HEIGHT
TRACK
MANUAL
LIFT
MOTOR
OPERATED
6’5” 10”, 12”, 14” Radius 89” 120”
6’5” Low Headroom 101” 120”
6’6” 10”, 12”, 14” Radius 90” 120”
6’6” Low Headroom 102” 120”
7’0” 10”, 12”, 14” Radius 96” 120”
7’0” Low Headroom 108” 120”
7’6” 10”, 12”, 14” Radius 102” 132”
7’6” Low Headroom 114” 132”
8’0” 10”, 12”, 14” Radius 108” 132”
8’0” Low Headroom 120” 132”
BACKROOM REQUIREMENT
TRACK TYPE
TorqueMaster
®
10”, 12” 10”
14” 12”
3-1/2” LHR 6”
LHR Kit 6 1/2”
P5
Recommended
tools from
page 5
Preparing the Opening
WEATHER SEAL
HEADROOM
BACKROOM
DOOR
WIDTH
DOOR HEIGHT
LEVEL HEADER
PLUMB JAMBS
HEADER BOARD
2” X 6” LUMBER
PREFERRED
SUITABLE MOUNTING
SURFACE 2” X 6”
LUMBER MINIMUM
HEADER
JAMB
JAMB
JAMB
WEATHER
SEAL
1/8” TO 1/4”
WARNING
FAILURE TO
SECURELY ATTACH A
SUITABLE MOUNTING PAD TO STRUCTURALLY
SOUND FRAMING COULD CAUSE SPRINGS TO
VIOLENTLY PULL MOUNTING PAD FROM WALL,
RESULTING IN SEVERE OR FATAL INJURY.
If you just removed your existing door or you are installing a
new door, complete all steps in PREPARING THE OPENING.
For detailed technical information regarding the opening
preparation, refer to the DASMA Technical Data Sheet TDS
#161 Connecting Garage Door Jambs to Building. Framing
located at www.dasma.com.
The inside of your garage door opening should be framed with
wood jambs and header. It is recommended that 2” x 6” lumber
be used. The jambs must be plumb and the header level. The
jambs should extend a minimum of 12” (305 mm) above the
top of the opening for TorqueMaster
®
counterbalance systems.
For low headroom applications, the jambs should extend to
the ceiling height. Minimum side clearance required, from the
opening to the wall, is 3-1/2”.
IMPORTANT: CLOSELY INSPECT JAMBS, HEADER AND
MOUNTING SURFACE. ANY WOOD FOUND NOT TO BE SOUND,
MUST BE REPLACED.
The jambs and header must be securely fastened to sound
framing members. Do not place jambs and header over drywall,
paneling, etc. Heads of fasteners must be flush or below jamb
and header surface, so they do not interfere with installation or
operation of new door.
TorqueMaster
®
counterbalance systems, a suitable mounting
surface must be firmly attached to the wall, above the header
at the center of the opening.
The mounting surface must be 2” x 6” lumber minimum (Select
southern yellow pine lumber. Do not use lumber marked as
spruce-pine-fur or SPF).
The mounting surface must be securely attached to block or
concrete wall with four (4) 3/8” masonry anchors or four (4)
5/16” x 4” lag screws for a wood structure.
NOTE: Drill a 3/16” pilot hole in the mounting surface to avoid
splitting the lumber. Do not attach the mounting surface with
nails.
WEATHER SEAL: Fit weather seal (may not be included) to fit
the jambs and header. Align the edge of the weather seals an
1/8” to 1/4” inside the edge of the opening. Temporarily nail
the weather seal to the jambs to keep the bottom section from
falling out of the opening during installation. Equally space
nails approximately 12” to 18” apart.
NOTE: Do not permanently attach weather seal to the jambs at
this time. Permanent installation will be done in Step 34.
HEADROOM REQUIREMENT: Headroom is defined as the
space needed above the top of the door for tracks, springs, etc.
to allow the door to open properly. If the door is to be motor
operated, 2-1/2” (64 mm) of additional headroom is required.
NOTE: 6” LHR Conversion Kit is available for 12” Radius only.
Contact your local Wayne-Dalton
®
dealer.
BACKROOM REQUIREMENT: Backroom is defined as the
distance needed from the opening back into the garage to
allow the door to open fully.