8.0 Troubleshooting
Water Column: Refer to section 5.1
Sensitivity/Conductivity: Refer to sections 2.2 and 3.2
Probes: Refer to sections 2.4, 3.5 and 5.2
Probe Wiring: Refer to sections 2.2, 2.5.1, 2.5.2, 2.5.7 and fig 4, 5 & 6
Line Power/Fuses: Refer to section 2.5.2 and 3.3.1
Power Supplies: Refer to section 3.3.1
S/W discrimination: Refer to section 4.0
Clock Fault/Backup: Refer to section 3.3.2
Electric Fault: Refer to section 3.3
Level Fault: Refer to sections 2.5.1 and 2.5.6
Continuity (Open/Short): Refer to section 3.3.3
Control Relay: Refer to section 2.5.4
Display Module Wiring: Refer to section 2.5.3 and fig 4, 5, 8, 9 & 10
LED Flash: Refer to section 2.5.3.1
The electronics module and display module(s) are constructed with surface mounted
electronics. Field repair is not practical except for replacement of relays.
9.0 Disposal at End of Useful Life
The Model 12B may be used in a variety of fluid applications. By following the appropriate
national and industry regulations, the user must determine the extent of preparation and
treatment the Model 12B must incur before its disposal. A Material Safety Data Sheet
(MSDS) may be required before disposal services accept certain components.
Metal, glass and polymers should be recycled whenever possible. Refer to order and
TV&C - Prophetstown Material Specification sheets for materials of construction.
RIGHT TO KNOW LAWS AND OSHA STANDARD 29CFR (1910.1200)
Material Safety Data Sheets on the following Penberthy product:
Model 12B
The OSHA Hazard Communication Standard 29CFR 1910.1200, states that the standard does not apply to “articles”. The standard defines an article
as:
*A manufactured item formed to a specific shape or design for a particular use which does not release or otherwise expose an employee
to a hazardous chemical under normal conditions of use”.
The above named products fall within the definition of an ‘article”, no Material Safety Data Sheets are available or are required. Our product is
manufactured as an “end product”.
If the product is a weld end the following applies.
WARNING: Materials used in manufacture of Penberthy products are considered in a stable condition when shipped. However, under certain
conditions purchasers could create potential hazardous conditions by their future operations.
Caution: Welding, cutting, burning, machining or grinding of this product can generate toxic dust and fumes of potentially hazardous ingredients. The
dust or fumes can cause irritation of the respiratory tract, nose, throat, skin and eyes. It may cause temporary or permanent respiratory disease in a
small percentage of exposed individuals. Use moderate ventilation when grinding or welding. Avoid breathing dust, fumes or mist. Avoid prolonged
skin contact with dust or mist. Maintain dust levels below OSHA and ACGIH levels. Use protective devices. Wash hands thoroughly after contact
with dust before eating or smoking.
For emergency information contact:
Tyco Valves & Controls, L.P. Prophetstown
320 Locust St., Prophetstown, Illinois 61277
Phone: 815-537-2311
Fax: 815-537-5365