Trane UNT-SVX07A-EN Air Conditioner User Manual


 
UNT-SVX07A-EN 37
electrical
requirementsInstallation
Table I-ER-4. Free discharge motors on units with two-row, electric, or steam coils
unit 115 volt 208-230 volt 277-480 volt rpm
size FLA hp (kW) FLA hp (kW) FLA hp (kW) H M L
02 0.6 .03 (.02) 0.3 .03 (.02) 0.2 .03 (.02) 980 840 655
03 0.7 .04 (.02) 0.4 .04 (.02) 0.3 .04 (.02) 980 780 580
04 0.9 .05 (.04) 0.5 .05 (.04) 0.4 .05 (.04) 1050 780 580
06 1.2 .07 (.05) 0.6 .07 (.05) 0.5 .07 (.05) 1030 780 580
08 1.4 .12 (.09) 0.9 .12 (.09) 0.6 .12 (.09) 1080 800 600
10 0.9 .05 (.04) 0.5 .05 (.04) 0.4 .05 (.04) 1050 780 580
1.2 .07 (.05) 0.6 .07 (.05) 0.5 .07 (.05) 1030 780 580
12 0.9 .05 (.04) 0.5 .05 (.04) 0.4 .05 (.04) 1050 780 580
1.4 .12 (.09) 0.9 .12 (.09) 0.6 .12 (.09) 108 800 600
Table I-ER-5. High static motors on units with two-row, electric, or steam coils
unit 115 volt 208-230 volt 277- 480 volt rpm
size FLA hp (kW) FLA hp (kW) FLA hp (kW) H M L
02 1.1 .07 (.05) 0.6 .07 (.05) 0.5 .07 (.05) 1480 1110 865
03 1.4 .08 (.06) 0.7 .08 (.06) 0.6 .08 (.06) 1400 1175 860
04 1.6 .10 (.07) 0.8 .10 (.07) 0.7 .10 (.07) 1475 1315 1070
06 2.6 .16 (.12) 1.2 .16 (.12) 1.0 .16 (.12) 1400 1070 855
08 3.4 .24 (.18) 1.4 .24 (.18) 1.1 .24 (.18) 1475 1285 975
10 1.6 .10 (.07) 0.8 .10 (.07) 0.7 .10 (.07) 1475 1315 1070
2.6 .16 (.12) 1.2 .16 (.12) 1.0 .16 (.12) 1400 1070 855
12 1.6 .10 (.07) 0.5 .10 (.07) 0.7 .10 (.12) 1475 1315 1240
3.4 .24 (.18) 0.9 .24 (.18) 1.1 .24 (.18) 1475 1285 975
Table I-ER-6. Free discharge motors on units with three and four-row coils
unit 115 volt 208-230 volt 277-480 volt rpm
size FLA hp(kW) FLA hpP (kW) FLA hp (kW) H M L
02 0.6 .03 (.02) 0.3 .03 (.02) 0.2 .03 (.02) 980 840 655
03 0.8 .05 (.04) 0.5 .05 (.04) 0.4 .05 (.04) 1080 800 600
04 1.0 .06 (.04) 0.6 .06 (.04) 0.5 .06 (.04) 1080 800 600
06 1.4 .12 (.09) 0.9 .12 (.09) 0.6 .12 (.09) 1080 800 600
08 1.7 .13 (.10) 1.0 .13 (.10) 0.8 .13 (.10) 1080 800 600
10 1.0 .06 (.04) 0.6 .06 (.04) 0.5 .06 (.04) 1080 800 600
1.4 .12 (.09) 0.9 .12 (.09) 0.6 .12 (.09) 1080 800 600
12 1.0 .06 (.04) 0.6 .06 (.04) 0.5 .06 (.04) 1080 800 600
1.7 .13 (.10) 1.0 .13 (.10) 0.8 .13 (.10) 1080 800 600
Table I-ER-7. High static motors on units with three and four-row coils
unit 115 volt 208-230 volt 277-480 volt rpm
size FLA hp (kW) FLA hp (kW) FLA hp (kW) H M L
02 1.1 .07 (.05) 0.6 .07 (.05) 0.5 .07 (.05) 1480 1110 865
03 1.3 .08 (.06) 0.7 .08 (.06) 0.5 .08 (.06) 1500 1355 1110
04 2.1 .13 (.10) 0.9 .13 (.10) 0.7 .13 (.10) 1580 1375 1240
06 3.4 .24 (.18) 1.4 .24 (.18) 1.1 .24 (.18) 1475 1285 975
08 3.4 .24 (.18) 1.4 .24 (.18) 1.1 .24 (.18) 1475 1285 975
10 2.1 .13 (.10) 0.9 .13 (.10) 0.7 .13 (.10) 1580 1375 1240
3.4 .24 (.18) 1.4 .24 (.18) 1.1 .24 (.18) 1475 1285 975
12 2.1 .13 (.10) 0.9 .13 (.10) 0.7 .13 (.10 ) 1580 1375 1240
3.4 .24 (.18) 1.4 .24 (.18) 1.1 .24 (.18) 1475 1285 975
Note: Actual rpm will vary with application and configuration. Size 10 & 12 units have two motors.
Table I-ER-2. Low vertical free discharge
motors, 115 volt
size FLA HP (kW) RPM
03 0.7 .03 (0) H 1090
M 770
L 560
04 0.8 .03 (0) H 1090
M 750
L 560
06 1.1 .03 (0) H 1115
M 760
L 560
Note:
Actual rpm will vary with application and configuration.
Table I-ER-3. Decimal to fractional HP (kW)
conversion
FC Decimal Fraction
02 .03 1/30
.07 1/15
03 .04 1/25
.05 1/20
.08 1/12
04 .05 1/20
.06 1/16
.10 1/10
.13 1/8
06 .07 1/15
.12 1/8
.16 1/6
.24 1/4
08 .12 1/8
.13 1/8
.24 1/4
10 .05 .07 1/20 1/15
.06 .12 1/16 1/8
.10 .16 1/10 1/6
.13 .24 1/8 1/4
12 .05 .12 1/20 1/8
.06 .13 1/16 1/8
.10 .24 1/10 1/4
.13 .24 1/8 1/4
low vertical .03 1/30
03, 04, 06
Note:
Values for fractional HP’s (kW’s) are approximate values and
not necessarily the actual HP (kW).