Model C006 Troubleshooting Guide
Section 7 Troubleshooting Guide
General Troubleshooting
Problem Probable Cause Remedy
1. Dispenser will not
operate.
a. Unit is not plugged in. a. Plug the unit into a
receptacle.
b. Power switch is in the
OFF position.
b. Place the power switch
in the ON position. The
power indicator light will
illuminate.
2. Dispenser will not
dispense product.
a. There is no product in
the unit; i.e., there is a
MIX OUT condition.
a. Add product to the fill
line and reset (full or
low fill level). Full = HI
(586 ml) and Low Fill =
LO (195 ml).
b. The product tube is
obstructed or kinked.
b. Clear the obstruction or
kink.
c. The product tube is not
properly aligned over
the pump rollers.
c. Realign the product
tube, centering it over
the pump rollers and
removing any slack.
(See page 21.)
d. Unit is in the 60 day
lockout.
d. Clean the unit. Then
press and hold the
CLEAN/CAL button for
4 seconds to reset the
cleaning cycle.