Model C006 Operating Procedures
Section 5 Operating Procedures
Assembly and Start Up
Step Action
1 Plug the machine into an approved receptacle. The power
indicator will illuminate on the front of the dispenser .
2 Open the front door to the dispenser.
3 Remove all tanks and lids.
ALWAYS FOLLOW LOCAL HEALTH CODES!
Cleaning/Sanitizing
Step Action
1 Prepare a sink with an approved 100 PPM
cleaning/sanitizing solution (example: Kay-5® or Stera
Sheen®). USE WARM WATER AND FOLLOW THE
MANUFACTURER'S SPECIFICATIONS.
2 Thoroughly wash, rinse, and sanitize all tanks and lids in
the sink.
3 Prepare 3 cleaning containers with an approved 100 PPM
cleaning/sanitizing solution.
4 Place one container on each shelf with product tubes in the
containers.
5 Prepare another cleaning container of cleaning/ sanitizing
solution.
6 Place the sugar feed tube in the cleaning/sanitizing
solution.
7 Press the CLEAN/CAL button. The screen will prompt the
operator to enter the access code. Use the size buttons to
enter the code as follows: 3 (MED) 2 ( SM) 1 (X-SM).
8 Upon entry, the screen will read “CLEAN PRESS FLVR”.
9 Press the CLEAN/CAL button once to display “CLEAN ALL
<1>”.