R-2397
22
1) Practice for checking total service counts
(eg; 234,567 Counts).
2) Practice for clearing Service's counts
" " : Flicker / : 0.1 sec BUZZER
PAD ORDER DISPLAY PHONE
(Door close) .
CHECK "NUMBER" . CHECK
CHECK 82 68 "CHECK"
(User's Total Counts)
#1 VOLUME 82 68 "CHECK"
VOLUME 82 68 "CHECK"
DOUBLE 2 34 56 7 "CHECK"
QUANTITY (Total Counts of Service)
SET 0 "CHECK"
0 0 "CHECK"
SET 0 "CHECK"
CHECK .
#1: Denotes the procedure for the servicer to disable clear-
ing. This procedure is instructed to service personnel only
and is excluded from the operation manual.
PROCEDURE FOR CHECKING/CLEARING
SERVICE COUNTS OF MICROWAVE OVEN
The following procedure enables the servicer to obtain the
total service counts (cook cycles) for memory cooking,
double quantity cooking and defrost. The maximum capacity
of the counter is 999,999 counts, above which the counter
will reset to "0". The counter will retain the total counts (will
not clear) in the event of a power disruption.
PAD
DISPLAY INDICATOR LED
PHONE
(Door close)
CHECK
CHECK 82 68#1
•
•
•
( user total count )
#2
VOLUME
VOLUME
DOUBLE
QUANTITY
2 34 56 7
( service total count )
CHECK
1 NUMBER 1
( after 1 sec. )
( filter used time )
2 NUMBER
( after 1 sec. )
( filter lim. time )
45
2
2 00
0 (No 10) NUMBER
10
( after 1 sec. )
( service total cook time )
35 43 2
CHECK
•
CHECK
NUMBER
0.1sec BUZZER
• • •
flashing
• • •
#1: Denotes total service counts within the reach of user, of
which checking and clearing practices are described in
this instruction manual.
#2: Denotes the procedure for the servicer to disable check-
ing/clearing. This procedure is instructed to service per-
sonnel only and is excluded from the operation manual.
1) How to enter the contents of DEFROST
T = STG1 + STG2 + STG3
STG = A x T + B
1 stage 10% power level
" " : Flicker / : 0.1 sec BUZZER
PAD ORDER DISPLAY PHONE
(Door close) .
SET .
SET "NUMBER" .
(within 2 sec.)
#1 START "NUMBER" .
DEFROST 1 0.00 DEF
9,9 1 0.99 DEF x 2
(A)
SELECTATIME 1 0 DEF
9 1 90 DEF
#2 (+ - B)
DEF "POWER"
SELECTAPOWER 1 90 100%
DEF "POWER"
1 90 10%
SELECTATIME 2 0.00 DEF
0 2 0.00 DEF
(A)
SELECTATIME 2 0 DEF
0 2 0 DEF
(+ - B)
SELECTATIME 3 0 DEF
START 3 A DEF
SET 4 . DEF
SET .
#1 : No key entry signal.
#2 : To set-B, touch the selectapower key twice.
PROCEDURE FOR ENTERING TO IC-2
When the control unit or IC-2 is exchanged, re-enter the
constants of DEFROST and the memory pads 1~20, refer-
ring to items 1 and 2 below.
2) How to enter the memory information
Example : Suppose cooking time 5 sec. and output power
100% are entered into the memory pad 1.
PAD ORDER DISPLAY PHONE
(Door close) .
SET .
SET "NUMBER" .
(within 2 sec.)
1 NUMBER 1 . 0
5 NUMBER 1 . 5
SET "NUMBER" .
SET .
Enter the memory information into the memory pads 1 ~10
referring to above example. The memory information are
given below.