Regency FP90 Indoor Fireplace User Manual


 
FPI FP90 Wood Fireplace 29
INSTALLATION
Installing the Facing Guide
1) Secure the left and right facing guides to the fi re-
place with seven (7) screws (#10 x 1”) on each
side. Holes must be pre-drilled.
2) Install the top louver opening adapter to the face
of the unit with fi ve (5) screws (¼-20 x ½”).
Installing the Excalibur Faceplate
3) Replace the left and right doors on the hinges.
1) Remove the left and right door from the fi replace.
NOTE: Before installing the fi replace the facing guide must be installed.
3) Attach the sides of the top louver opening adapter
to the left and right facing guides with two (2)
screws (#8 x ½”).
Optional:
4) Install the optional masonry cover plate to the
facing guides with four (4) screws (¼-20 x ½”).
2) Put the Excalibur faceplate in place and secure
with four (4) screws (¼-20 x ½”) making sure that
the faceplate is centered.
WARNING: Keep masonry
material at least 1/2” (13mm)
from this top facing guide. This
is required to prevent masonry
facing material from hitting the
top stiffener located on the back
of the surround which is higher
than this edge.
EXCALIBUR FACEPLATE INSTALLATION
INSTALLATION